GWZC-9000 Remote Terminal Unit (RTU) Communication Panel

Application:Used in PV plants, substations, power plants, and power automation systems for protocol conversion, data acquisition, and transmission.
Protocol Conversion: Supports mutual conversion and uplink of Modbus, IEC 103/104, IEC 61850, and TCP/IP.
Data Handling: Acquires data from protection relays/power meters, converts it to SCADA/dispatch-compliant protocols, and transmits to master stations/dispatch systems.

Main Transformer Protection Panel
details
GWZC-9000 Main Transformer Protection Panel

Application Scope : The GWZC-9000 main transformer protection control panel is designed for the protection and control of medium to large capacity main transformers with voltage levels of 11kV, 33kV, 69kV, 115kV,132.

Product functions(ANSI):87H | 87 | 87A | 60 | 50/51 | 51 | 50N/51N | 51N | 49 | 50G/51G | 38/74 | 59 | 59N | 27 | 74 | 60 | 27/81U | 27/81L | 30 | 71G | 26/49 | 63 | 38

Generator Protection Panel
details
GWZC-9000 Generator protection panel​

Product Overview : The ​GWZC-9000 generator protection panel is mainly used for the control and protection of hydroelectric units, gas turbine units, biogas units, and large diesel generator sets.

Product functions(ANSI):87H | 87 | 87A | 49 | 50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74 | 50N/51N | 50G/51G

Product Components : GWZC-9884 Generator Differential Protection Relay | GWZC-9885 Generator Rotor Earth Fault Protection Relay | GWZC-9886 Generator Backup Protection Relay | Panel and accessories

GWZC-9605 Public Measurement and Control Device
details
GWZC-9605 Public Measurement and Control Device

Product Overview : The ​GWZC-9605  is a ​35kV/substation​ protection and control relay with ​measurement, switching, communication (IEC 61850/Modbus), and fault logging, used in ​switchgear and industrial power systems.

Product functions(ANSI):25 | 51N | 59N

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9603 Reverse Power Protection Relay
details
GWZC-9603 Reverse Power Protection Relay (ANSI 32)

Product Overview : The ​GWZC-9603​ reverse power relay detects and blocks reverse power flow in 6.6kV-33kV systems, with adjustable trip settings for generator and grid protection in switchgear applications.

Product functions(ANSI):50 | 51 | 49 | 50N/51N | 32 | 32R | 79 | 59 | 27 | 59N | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9601 Fault Islanding Protection Device
details
GWZC-9601 Fault Islanding Protection Device

Product Overview : GWZC-9601​ is a fault disconnection relay for ​10-35kV grids, detecting and isolating faults (overcurrent, undervoltage, frequency issues) to prevent system failures.

Product functions(ANSI):59N | 27 | 59 | 81U | 81O | 78 | 60 | 94

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9681 Generator Backup Protection Relay
details
GWZC-9681 Generator Backup Protection Relay

Product Overview : The ​GWZC-9681​ is a generator backup relay for 10kV–35kV systems, offering overcurrent, under/overvoltage, and reverse power protection. Installed in generator panels, it ensures fault backup security.

Product functions(ANSI):50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9682 Generator Rotor Earth Fault Protection Relay
details
GWZC-9682 Generator Rotor Earth Fault Protection Relay

Product Overview : GWZC-9682 Rotor Earth Fault Relay​ – Provides two-stage protection (alarm/trip) with insulation monitoring for generator rotors, preventing winding damage. Installed in protection/excitation panels.

Product functions(ANSI):50N/51N | 50G/51G

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9683 Generator Differential Protection Relay
details
GWZC-9683 Generator Differential Protection Relay(87G)

Product Overview : The ​GWZC-9683 ​ is a generator differential relay offering fast fault protection with harmonic restraint, ideal for power plants and industrial generators (6.6kV–24kV).

Product functions(ANSI):87H | 87 | 87A | 49

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9829 Main Transformer On-load Tap Changer Control Relay
details
GWZC-9694 Main Transformer On-load Tap Changer Control Relay

Product Overview : The GWZC-9694 relay provides on-load tap changer control for 66kV/110kVpower transformers, enabling tap position monitoring and voltage regulation.

Product functions(ANSI):94 | 90

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

Technical Knowledge More
Transformer Protection Relay Panel
Renovation Scheme for Unattended Automatic System of Hydropower Station
The core of the transformation of the unattended automation system for hydropower stations is to upgrade the traditional manually attended power station into a modern intelligent power station with "unattended operation and minimal personnel on duty" through computerized monitoring, intelligent sensing, reliable communication and remote centralized control. It realizes remote monitoring, automatic control, fault self-diagnosis and safety early warning, greatly reducing labor costs and improving operational efficiency and safety. Among them, the secondary electrical system, as the "nervous system, brain and safety line of defense" of the power station, is the core support for the unattended transformation. Without a reliable secondary system, true unattended operation cannot be achieved. Therefore, this integration will focus on improving the detailed content of secondary electrical equipment while retaining the full process details of the transformation.
2026/04/21
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.