Product

Low-voltage load shedding panel
details
GWZC-9000 Low-voltage load shedding panel

Application Scope : The GWZC-9000 low-frequency and low-voltage load shedding panel is a critical protection device in power systems. It automatically sheds non-essential loads according to preset sequences when system frequency or voltage abnormally drops, preventing system collapse.

Product functions(ANSI):827 | 59 | 81U | 81O | 60

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

RTU Communication Panel
details
GWZC-9000 Remote Terminal Unit (RTU) Communication Panel

Application:Used in PV plants, substations, power plants, and power automation systems for protocol conversion, data acquisition, and transmission.
Protocol Conversion: Supports mutual conversion and uplink of Modbus, IEC 103/104, IEC 61850, and TCP/IP.
Data Handling: Acquires data from protection relays/power meters, converts it to SCADA/dispatch-compliant protocols, and transmits to master stations/dispatch systems.

Main Transformer Protection Panel
details
GWZC-9000 Main Transformer Protection Panel

Application Scope : The GWZC-9000 main transformer protection control panel is designed for the protection and control of medium to large capacity main transformers with voltage levels of 11kV, 33kV, 69kV, 115kV,132.

Product functions(ANSI):87H | 87 | 87A | 60 | 50/51 | 51 | 50N/51N | 51N | 49 | 50G/51G | 38/74 | 59 | 59N | 27 | 74 | 60 | 27/81U | 27/81L | 30 | 71G | 26/49 | 63 | 38

Generator Protection Panel
details
GWZC-9000 Generator protection panel​

Product Overview : The ​GWZC-9000 generator protection panel is mainly used for the control and protection of hydroelectric units, gas turbine units, biogas units, and large diesel generator sets.

Product functions(ANSI):87H | 87 | 87A | 49 | 50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74 | 50N/51N | 50G/51G

Product Components : GWZC-9884 Generator Differential Protection Relay | GWZC-9885 Generator Rotor Earth Fault Protection Relay | GWZC-9886 Generator Backup Protection Relay | Panel and accessories

GWZC-9801 Public Measurement and Control Device
details
GWZC-9801 Public Measurement and Control Device

Product Overview : The ​GWZC-9801​ is a ​35kV/substation​ protection and control relay with ​measurement, switching, communication (IEC 61850/Modbus), and fault logging, used in ​switchgear and industrial power systems.

Product functions(ANSI):25 | 51N | 59N

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9790N Reverse Power Protection Relay
details
GWZC-9790N Reverse Power Protection Relay (ANSI 32)

Product Overview : The ​GWZC-9790N​ reverse power relay detects and blocks reverse power flow in 6.6kV-33kV systems, with adjustable trip settings for generator and grid protection in switchgear applications.

Product functions(ANSI):50 | 51 | 49 | 50N/51N | 32 | 32R | 79 | 59 | 27 | 59N | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9890J Fault Islanding Protection Device
details
GWZC-9890J Fault Islanding Protection Device

Product Overview : GWZC-9890J​ is a fault disconnection relay for ​10-35kV grids, detecting and isolating faults (overcurrent, undervoltage, frequency issues) to prevent system failures.

Product functions(ANSI):59N | 27 | 59 | 81U | 81O | 78 | 60 | 94

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9886 Generator Backup Protection Relay
details
GWZC-9886 Generator Backup Protection Relay

Product Overview : The ​GWZC-9886​ is a generator backup relay for 10kV–35kV systems, offering overcurrent, under/overvoltage, and reverse power protection. Installed in generator panels, it ensures fault backup security.

Product functions(ANSI):50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9885 Generator Rotor Earth Fault Protection Relay
details
GWZC-9885 Generator Rotor Earth Fault Protection Relay

Product Overview : GWZC-9885 Rotor Earth Fault Relay​ – Provides two-stage protection (alarm/trip) with insulation monitoring for generator rotors, preventing winding damage. Installed in protection/excitation panels.

Product functions(ANSI):50N/51N | 50G/51G

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9884 Generator Differential Protection Relay
details
GWZC-9884 Generator Differential Protection Relay(87H | 87 | 87A)

Product Overview : The ​GWZC-9884​ is a generator differential relay offering fast fault protection with harmonic restraint, ideal for power plants and industrial generators (6.6kV–24kV).

Product functions(ANSI):87H | 87 | 87A | 49

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11