Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Product

GWZC-9828 Transformer Non-Electrical Protection Relay
details
GWZC-9693 Transformer Non-Electrical Protection Relay

Product Overview : Transformer Non-Electrical Protection Relay​ monitors oil temperature, gas, and pressure in transformers (35kV+). Installed on transformers or in control cabinets, it provides alarms/trips to prevent failures. Essential for substations and power plants, it complements electrical protection systems.

Product functions(ANSI):71G | 26/49 | 63 | 38

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9692 Transformer Backup Protection Relay
details
GWZC-9692 Transformer Backup Protection Relay

Product Overview : GWZC-9692​ is a transformer backup protection relay for 66kV/33kV/11kV systems, providing overcurrent, earth fault and overload protection. Installed in switchgear, it offers secondary protection with IEC 61850/Modbus support.

Product functions(ANSI):50/51 | 51 | 50N/51N | 51N | 49 | 50G/51G | 38/74 | 59 | 59N | 27 | 74 | 60 | 27/81U | 27/81L | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9691 Main Transformer Differential Protection Relay
details
GWZC-9691 Main Transformer Differential Protection Relay(87T)

Product Overview: GWZC-9691​ is a fast-acting (<30ms) ​transformer differential relay​ for ​33kV–110kV systems, featuring harmonic restraint. Used in substations and industrial plants for transformer protection.

Product functions(ANSI):87H | 87 | 87A | 60

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9631Y Motor Magnetic Balance Differential Protection Relay
details
GWZC-9631Y Motor Magnetic Balance Differential Protection Relay (87M)

Product Overview : GWZC-9631Y ​ provides magnetic balance differential protection for HV motors, with overcurrent and thermal protection. Installed in motor control centers, it safeguards critical industrial motors with fault recording capability.

Product functions(ANSI):87M | 50 | 51 | 51 | 51 | 49 | 48 | 50Q | 46 | 46 | 50N/51N | 49 | 48 | 86 | 59 | 27 | 59N | 81O | 81U | 60FL | 27 | 74 | 27/81U | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9662 Incoming Line Auto-transfer Relay
details
GWZC-9662 Incoming Line Auto-transfer Relay (50/27)

Product Overview : The ​GWZC-9662 Auto-Transfer Relay​ ensures ​uninterrupted power supply​ by automatically switching to backup sources in ​35kV substations and industrial plants. It features ​voltage/current monitoring, programmable delays, and fault logging, with ​IEC 61850/Modbus support.

Product functions(ANSI):50/27 | 50/51 | 51 | 49 | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9652 PT synchronizing relay
details
GWZC-9652 PT Paralleling relay

Product Overview: GWZC-9652 PT Paralleling Relay​ ensures safe synchronization in 33kV/66kV systems through phase, frequency and voltage matching. Prevents out-of-phase closing with adjustable thresholds. Installed in switchgear and generator panels.

Product functions(ANSI):59 | 59N | 27/59

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9642 Capacitor switching relay
details
GWZC-9642 Capacitor switching relay

Product Overview: The GWZC-9642 capacitor switching relay provides protection, control and monitoring for capacitor banks in 110kV and below systems, with installation in substations and industrial plants.

Product functions(ANSI):87H | 87 | 50/51 | 51 | 46 | 50N/51N | 59 | 27 | 47 | 74 | 74T | 30 | 25

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9631CMotor Differential Protection Relay GWZC-983
details
GWZC-9631C Motor Differential Protection Relay (87M)

Product Overview : GWZC-9631C Motor Differential Protection Relay for HV/LV motors (11kV-400V), detecting internal faults with CT supervision. Installed in MCCs and switchgear for fast fault clearance in industrial/power applications.

Product functions(ANSI):87H | 87 | 50 | 51 | 51 | 51V | 49 | 48 | 46 | 46 | 46V | 50N/51N | 49 | 48 | 86 | 59 | 27 | 59N | 81O | 81U | 60FL | 60 | 74 | 27/81U | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9621C Transformer Differential Protection Relay
details
GWZC-9621C Transformer Differential Protection Relay (87T)

Product Overview: The ​GWZC-9621C​ is a transformer differential relay that detects internal faults while preventing inrush false trips. Installed in substation panels, it provides reliable protection for power transformers in utility/industrial systems.

Product functions(ANSI):87T | 87 | 87AL | 50/51 | 51V | 49 | 46 | 46 | 50N/51N | 51N | 59 | 27 | 59N | 60FL | 60 | 60CT | 74 | 27D | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9694 Low-Frequency Low-Voltage Load Shedding Device
details
GWZC-9694 Low-Frequency Low-Voltage Load Shedding Device

Product Overview : GWZC-9694Underfrequency/Undervoltage Load Shedding (UFUVLS) device is a grid protection system that automatically cuts loads to maintain stability during frequency drops or voltage dips, preventing blackouts in renewable-rich power networks.

Product functions(ANSI):27L1, 27L2, 27L3 | 59L1, 59L2, 59L3 | 81L1, 81L2, 81L3 | ​81O1, 81O2, 81O3

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Transformer Protection Relay Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.
2025/11/24
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my