Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Product

GWZC-9890L Low-Frequency Low-Voltage Load Shedding DeviceGWZC-9890L Low-Frequency Low-Voltage Load Shedding Device
details
GWZC-9890L Low-Frequency Low-Voltage Load Shedding Device

Product Overview : GWZC-9890L Underfrequency/Undervoltage Load Shedding (UFUVLS) device is a grid protection system that automatically cuts loads to maintain stability during frequency drops or voltage dips, preventing blackouts in renewable-rich power networks.

Product functions(ANSI):27L1, 27L2, 27L3 | 59L1, 59L2, 59L3 | 81L1, 81L2, 81L3 | ​81O1, 81O2, 81O3

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9811C Line differential protection relay
details
GWZC-9811C Line differential protection relay (87H | 87)

Product Overview : The GWZC-9811C line differential protection relay is specifically designed for power distribution systems up to 66kV, featuring pilot-wire differential protection technology for fast fault clearance.

Product functions(ANSI):87H | 87 | 87A | 50 | 51 | 51V | 49 | 46 | 50N/50G | 59 | 27 | 81 | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9871 Bus Tie Protection & Control Relay
details
GWZC-9871 Bus Tie Protection & Control Relay

Product Overview : GWZC-9871 Bus Tie Protection and Control Relay is designed for bus charging protection or bus tie protection and monitoring & control in power systems with voltage levels up to 110kV.

Product functions(ANSI):51V | 50N/51N | 27/59 | IEC 61850: XCBR.Alm
Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9861 Bus-Tie Automatic Transfer Protection Relay
details
GWZC-9861 Bus-Tie Automatic Transfer Protection Relay

Product Overview:GWZC-9861 Bus-Tie Automatic Transfer Protection Relay is suitable for automatic transfer of incoming line switches, inner bridge switches, and main transformer switches at voltage levels below 110kV. It can be installed in panel assemblies or locally within switchgear cabinets.

Product functions(ANSI):50/51 | 51VI | 49 | 74
Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9851 PT protection relay
details
GWZC-9851 PT protection relay

Product Overview : The ​GWZC-9851 PT Protection Relay​ provides ​overvoltage and undervoltage protection​ for ​110kV and below​ busbar PTs, typically installed in ​switchgear cabinets​ for voltage monitoring.
Product functions(ANSI): 59 | 27 | 59N | IEC 61850: XCBR.AlmCCS/MMXU.AlmPTFF
Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9811  Line protection relay
details
GWZC-9811 Line protection relay

Product Overview : GWZC-9811 Line Protection Relay is designed for the protection of 33kV & 66kV transmission lines and feeder circuits, featuring easy installation and simple commissioning.
Product functions(ANSI):51P/27 | 51I | 51N | 49 | 46 | 59/27/59N
Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZW-9883  Generator Comprehensive Protection Relay
details
GWZW-9883 Generator Comprehensive Protection Relay

 Product Overview:The VIP-96S88C is a generator comprehensive protection relay that integrates differential protection and backup protection.

Product functions(ANSl):87G;60FL;50;50N;51;51N;51AC;40;49;46;46IT;58/59N;60FL;74;81L/81R

Communication functions:Ethernet 103, MODBUS RTU, 2×ETH, 2×RS485

GWZC-9841 Capacitor protection relay
details
GWZC-9841 Capacitor protection relay

Product Overview:The Capacitor Protection Relay​ is designed for ​low-voltage (LV) and medium-voltage (MV) capacitor bank protection​ and is typically installed in ​switchgear cabinets​ within substations, industrial plants, and power distribution systems.

Product functions(ANSI)51P | 67P | 51PI | 51N | 67N | 59 | 27 | 47 | 74 | 63 | 49 | 38

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9831 Motor protection relay
details
GWZC-9831 Motor protection relay

Product Overview : GWZC-9831 Motor Protection Relay Designed specifically for 0.4kV and 10kV motor protection applications, this relay enhances motor reliability, safety, and automation levels in industrial and power distribution systems.
Product functions(ANSI):50/51 | 49 | 48 | 46 (Stage I) | 51N/50N | 48LR | 66 | 59 | 27 | 59N | 81O | 81U | 60FL | 27X | 74 | 50BF | 38 | 49T
Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9821 Transformer protection relay
details
GWZC-9821 Transformer protection relay

Product Overview : GWZC-9821 Transformer Protection Relay Specifically designed for power transformers, this device is installed in switchgear cabinets of substations and industrial power distribution systems to ensure safe and reliable operation of transformers.
Product functions(ANSI):51P/27 | 51I | 51N | 49 | 46 | 59/27/59N
Communication functions :​​ IEC61850 | IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my