Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Bus coupler protection relay related product

GWZC-9872 Loop closing protection relay
details
GWZC-9872 Loop closing protection relay

Product Overview : The GWZC-9872 Loop Closing Protection Relay provides advanced loop closing protection for high-voltage power systems. Key features include automatic loop detection, synchronization verification, and fault isolation. Designed for installation in substation control panels, it is ideal for utility grid applications.

Product functions(ANSI):51V | 51 | 51 | 51N | 67 | 50N | 51N | 51N | 59 | 27 | 47 | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9561  Automatic Transfer Switch (ATS)​​
details
GWZC-9561 Automatic Transfer Switch (ATS)​​

Product Overview : The ​GWZC-9561 Automatic Transfer Switch (ATS)​​ automatically switches power sources to ensure uninterrupted supply, with voltage/frequency monitoring and fault protection for critical facilities. Complies with IEC/IEEE standards.

Product functions(ANSI):50/27| 50/51| 79| 60| 74

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9661 Bus Tie Protection & Control Relay
details
GWZC-9661 Bus Tie Protection Relay

Product Overview : GWZC-9661 Bus Tie Protection and Control Relay is designed for bus charging protection or bus tie protection and monitoring & control in power systems with voltage levels up to 110kV.

Product functions(ANSI):51V | 50N/51N | 27/59 | IEC 61850: XCBR.Alm
Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9663 Bus-Tie Automatic Transfer Protection Relay
details
GWZC-9663 Bus-Tie Automatic Transfer Protection Relay

Product Overview:GWZC-9663 Bus-Tie Automatic Transfer Protection Relay is suitable for automatic transfer of incoming line switches, inner bridge switches, and main transformer switches at voltage levels below 110kV. It can be installed in panel assemblies or locally within switchgear cabinets.

Product functions(ANSI):50/51 | 51VI | 49 | 74
Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Transformer Protection Relay Panel
Renovation Scheme for Unattended Automatic System of Hydropower Station
The core of the transformation of the unattended automation system for hydropower stations is to upgrade the traditional manually attended power station into a modern intelligent power station with "unattended operation and minimal personnel on duty" through computerized monitoring, intelligent sensing, reliable communication and remote centralized control. It realizes remote monitoring, automatic control, fault self-diagnosis and safety early warning, greatly reducing labor costs and improving operational efficiency and safety. Among them, the secondary electrical system, as the "nervous system, brain and safety line of defense" of the power station, is the core support for the unattended transformation. Without a reliable secondary system, true unattended operation cannot be achieved. Therefore, this integration will focus on improving the detailed content of secondary electrical equipment while retaining the full process details of the transformation.
2026/04/21
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my