Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Product

GWZC-9000 Sewage Treatment Automation Control System
details
GWZC-9000 Sewage Treatment Automation Control System

The GWZC-9000 sewage treatment automation control system integrates advanced control, monitoring, and protection technologies to enhance the efficiency, reliability, and safety of the sewage treatment process. The system automates key functions such as pump station control, flow regulation, water quality monitoring, and fault detection, reducing manual intervention and minimizing downtime. It employs intelligent protection relays, programmable logic controllers (PLCs), and remote terminal units (RTUs) to collect realtime data on water quality, flow rate, and equipment status.

GWZC-9000 Drainage Pumping Station Automation System
details
GWZC-9000 Drainage Pumping Station Automation System

The GWZC-9000 Drainage Pumping Station Automation System integrates PLC controllers, level sensors, and remote telemetry to automate floodwater management. It monitors realtime water levels, pump status, and flow rates using ultrasonic sensors and IoT gateways, triggering pump sequencing during heavy rainfall or rising tides. SCADA enables remote operation via HMI dashboards, while embedded algorithms optimize pump runtime to prevent overflow and reduce energy costs. With fault diagnostics (motor failures, blockage alerts) and SMS/cloud alarms, it minimizes urban flooding risks.

GWZC-9802 Directional Earth Fault Relay
details
GWZC-9802 Directional Earth Fault Relay (DEF Relay)

Product Overview : The ​GWZC-9802​ Directional Earth Fault Relay provides accurate directional impedance measurement for earth faults, featuring ANSI 67N protection, ±1% angle accuracy, and 4ms response time. It supports IEC 61850, Modbus, and DNP3.0 communication, operating in harsh environments from -40°C to +85°C to prevent cascading failures.

Product functions(ANSI):67N | 21 | 50/51

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9000 PV Plant SCADA System
details
GWZC-9000 Integrated Automation System for Photovoltaic Power Plants

The GWZC-9000 integrated automation system for photovoltaic power plants incorporates advanced control, monitoring, and protection technologies to enhance operational efficiency, reliability, and safety. The system automates critical functions such as circuit breaker operation, load switching, fault detection, and isolation, reducing manual intervention and minimizing downtime. It utilizes intelligent protection relays, programmable logic controllers (PLCs), and remote terminal units (RTUs) to collect real-time data on voltage, current, power quality, and equipment status.

GWZC-9000 Hydropower Plant Automation System
details
GWZC-9000 Hydropower Plant Automation System

The GWZC-9000 hydropower plant  automation system incorporates advanced control, monitoring, and protection technologies to enhance operational efficiency, reliability, and safety. It automates critical functions such as generator control, load distribution, fault detection, and isolation, minimizing manual intervention and reducing downtime. The system utilizes intelligent protection relays, programmable logic controllers (PLCs), and remote terminal units (RTUs) to collect real-time data on voltage, current, power quality, and equipment status.

GWZC-9887 Generator-Transformer Differential Protection Relay
details
GWZC-9887 Generator-Transformer Differential Protection Relay (87G|87T)

Product Overview: GWZC-9887 Generator-Transformer Differential Protection Relay provides complete differential protection for generator-transformer units. Features percentage differential protection, harmonic restraint, and IEC61850 communication support. Installs in switchgear panels for medium-small generator-transformer protection.

Product functions(ANSI):87H | 87 | 87A | 87B | 71M | 71T | 38 | 49 | 71O | 63PR | 27/81U | 40

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9000 20kV&33kVSubstation Automation System(SAS)
details
GWZC-9000 20kV & 33kV Substation Automation System (SAS)

The GWZC-900020kV & 33kV Substation Automation System (SAS)​​ integrates ​intelligent protection relays, PLCs, and RTUs​ to automate critical functions such as ​circuit breaker control, fault detection, load management, and power quality monitoring. This system ensures ​real-time data acquisition, remote operation, and rapid fault isolation, minimizing downtime and improving grid resilience.

GWZC-9000 6kV & 11kV Switching Station Automation System
details
GWZC-9000 6kV & 11kV switching station automation system

The GWZC-9000 6kV & 11kV switching station automation system integrates advanced control, monitoring, and protection technologies to enhance the efficiency, reliability, and safety of medium-voltage power distribution. This system automates key functions such as circuit breaker operation, load switching, fault detection, and isolation, reducing manual intervention and minimizing downtime. It employs intelligent electronic devices (IEDs), programmable logic controllers (PLCs), and remote terminal units (RTUs) to collect real-time data on voltage, current, power quality, and equipment status.

details
GWZC-9000 Fault recorder panel (​FRP) (ANSI 21)

Introduction : The Fault Recorder Panel (FRP) serves as the “black box” of power systems, capturing real-time voltage/current waveforms and digital signals during faults to provide critical data for fault analysis and protection verification. ​(ANSI 21)

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

GWZC-9812 Distance protection relay
details
GWZC-9812 Distance protection relay(21 | 21G | 21FL)

Product Overview : The ​GWZC-9812 Distance Protection Relay​ provides directional line protection (distance, current, voltage) and three-phase auto-reclosing for distribution systems below 35kV.

Product functions(ANSI):21 | 21G | 21FL | 68 | 50/51 | 50N/51N | 32 | 27 | 79 | 50HS/79 | 49 | 81U | 60FL

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my