Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Product

GWZC-9890D Anti-islanding protection relay
details
GWZC-9890D Anti-islanding protection relay(AIP)

Product Overview : GWZC-9890D Anti-islanding Protection Relay is designed for distributed generation systems, providing comprehensive protection, measurement, and control functions at grid interconnection points. It effectively prevents islanding conditions and ensures safe operation of distributed power sources.

Product functions(ANSI):81O| 81U| 59| 27| 81R | 32 | 94 | 67 | 50N/51N | 59N | 79 | 60FL | 50H/51H

Communication functions : IEC61850 |IEC 60870-5-103 |MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9651 VT (Voltage Transformer) Protection Relay
details
GWZC-9651 VT (Voltage Transformer) Protection Relay

Product Overview : The GWZC-9651 VT Protection Relay​ protects VTs (11kV-400kV) by detecting voltage faults. Used in substations to ensure accurate protection measurements.

Product functions(ANSI):59 | 27 | 59N/27N

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9661 Automatic Transfer Switch (ATS)​​
details
GWZC-9661 Automatic Transfer Switch (ATS)​​

Product Overview : The ​GWZC-9661 Automatic Transfer Switch (ATS)​​ automatically switches power sources to ensure uninterrupted supply, with voltage/frequency monitoring and fault protection for critical facilities. Complies with IEC/IEEE standards.

Product functions(ANSI):50/27| 50/51| 79| 60| 74

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9641 Capacitor protection relay
details
GWZC-9641 Capacitor protection relay

Product Overview : GWZC-9641 ​Capacitor Protection Relay​ provides overcurrent, over/undervoltage, unbalance, and thermal protection for shunt capacitor banks, with inrush restraint.

Product functions(ANSI):50 | 51 | 59 | 27 | 50N/51N | 46 | 47

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9631 Motor Protection Relay
details
GWZC-9631 Motor Protection Relay

Product Overview : GWZC-9631 Motor Protection Relay​ safeguards asynchronous motors (≤1600kW) against overload, short-circuit, and voltage/phase faults. Features motor control, monitoring, and Modbus communication. Installs in MCCs for industrial applications like pumps and compressors.

Product functions(ANSI):50 | 51 | 46 | 46 | 49 | 48 | 50N/51N | 27 | 49 | 99 | 86 | 90

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9621 Distribution transformer protection relay
details
GWZC-9621 Distribution transformer protection relay

Product Overview : GWZC-9621 GWZC-9621​ Distribution transformer protection relay safeguards ≤1600kVA station/grounding transformers (≤35kV) with integrated monitoring, designed for LV switchgear.

Product functions(ANSI):50/51/27 | 51 | 46 | 50G/51G | 49 | 59 | 27 | 74

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9611 Feeder Protection Relay
details
GWZC-9611 Feeder Protection Relay

Product Overview : GWZC-9611 Feeder Protection Relay​ Protects, controls (auto-reclosing), and monitors ​MV distribution feeders (11kV-33kV)​. Installed in ​substation/industrial feeder switchgear​ to safeguard outgoing circuits.

Product functions(ANSI):50 | 51 | 50N | 51N | 49 | 79 | 50 | 81U | 27 | 64

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9913 FO Line Diff Relay(87L)
details
GWZC-9913 FO Line Diff Relay(87L)

Product Overview : This FO Line Diff Relay protects 132kV and below transmission lines in ungrounded/low-resistance systems, offering primary/backup protection with monitoring. Supports switchgear/panel mounting via fiber channels with E1 interface.

Product functions(ANSI):87L |50/51 | 51 |50N/51N | 51N | 81U | 49 | 79 | 60 | 60 | 60 | 60/51 | 94 |21

Communication functions : IEC61850 | IEC 60870-5-103 |MODBUS RTU |2× Ethernet Ports | 2× RS-485

GWZC-9916 Bus differential protection relay
details
GWZC-9916 Bus differential protection relay

Product Overview : GWZC-9916 Bus Differential Protection Relay Applicable for voltage levels up to 132kV, supporting various busbar configurations including single bus, sectionalized single bus, triple-section single bus, double bus, double bus with single section, and double bus with double sections.

Product functions(ANSI):87 | 50BF | 50BF | 50 | 60 | 60 | 60 | 50 | 27

Communication functions : IEC61850 |​​IEC 60870-5-103 |MODBUS RTU |3× Ethernet Ports |3× RS-485

GWZC-9000 Power measurement and control panel
details
GWZC-9000 Power measurement and control panel

Application Scope : The Power Measurement and Control Panel is a key substation automation device. It monitors and controls auxiliary equipment (like DC systems, station power, fire protection), featuring data acquisition, communication, alarms, and IEC 61850-compliant remote control.

Product functions(ANSI):60 | 59N | 25 | 59 | 50/51 | 50N/51N | 94

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my