Home -Numeric protection panel​
GWZC-9000 Busbar Protection Panel
GWZC-9000 Busbar Protection Panel
GWZC-9000 Busbar Protection Panel

Applicable Scope: Designed for busbar protection in substations from 10kV to 500kV systems. Technical parameters include operating voltage up to 132kV, current ratings of 1A or 5A, and fault detection time less than 20ms. Suitable for industrial and utility applications where high reliability is critical.

Product functions(ANSI):87 | 50BF | 50BF | 50 | 60 | 60 | 60 | 50 | 27

Communication functions:IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 3× Ethernet Ports | 3× RS-485

Product Introduction Technical Parameter Size

GWZC-9000 Busbar Protection Panel Product Introduction:

          The GWZC-9000 Busbar Protection Panel is engineered for robust and fast protection of electrical busbars in high-voltage systems. It utilizes advanced algorithms for precise fault detection and isolation, minimizing downtime. With seamless integration into automation networks, it supports real-time monitoring and control. The panel is built for durability and ease of maintenance, making it ideal for critical infrastructure.

GWZC-9000 Busbar Protection Panel Technical Features:

  1. High-performance 32-bit processor with 128MB flash memory for efficient data handling
  2. Measures three-phase currents, voltages, frequency, and power parameters with high accuracy
  3. Configurable with 8 analog inputs, 16 digital inputs, and 10 relay outputs for flexible I/O setup
  4. Programmable protection logic using user-friendly software for custom protection schemes
  5. Dedicated operation circuit with trip and close outputs for breaker control
  6. Supports time synchronization via GPS or IRIG-B for event sequencing
  7. Incorporates TV (transient voltage) anti-maloperation feature to prevent false trips
  8. Communication interfaces include RS485 and Ethernet ports for Modbus and IEC61850 protocols
  9. Built-in waveform recording with storage for up to 100 events for fault analysis
  10. Low power consumption, typically less than 10W, for energy efficiency
  11. High EMC immunity, meeting IEC 60255-26 standards for electromagnetic compatibility
  12. Operating temperature range from -40°C to +85°C, suitable for harsh environments
Related products More
GWZC-9000 Fault recorder panel (​FRP) (ANSI 21)
detail
GWZC-9000 Power measurement and control panel
GWZC-9000 Power measurement and control panel
detail
GWZC-9000 Low-voltage load shedding panel
Low-voltage load shedding panel
detail
GWZC-9000 Remote Terminal Unit (RTU) Communication Panel
RTU Communication Panel
detail
GWZC-9000 Main Transformer Protection Panel
Main Transformer Protection Panel
detail
Technical Knowledge More
Transformer Protection Relay Panel
Renovation Scheme for Unattended Automatic System of Hydropower Station
The core of the transformation of the unattended automation system for hydropower stations is to upgrade the traditional manually attended power station into a modern intelligent power station with "unattended operation and minimal personnel on duty" through computerized monitoring, intelligent sensing, reliable communication and remote centralized control. It realizes remote monitoring, automatic control, fault self-diagnosis and safety early warning, greatly reducing labor costs and improving operational efficiency and safety. Among them, the secondary electrical system, as the "nervous system, brain and safety line of defense" of the power station, is the core support for the unattended transformation. Without a reliable secondary system, true unattended operation cannot be achieved. Therefore, this integration will focus on improving the detailed content of secondary electrical equipment while retaining the full process details of the transformation.
2026/04/21
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25