GWZC-9000 20kV&33kVSubstation Automation System(SAS)
GWZC-9000 20kV&33kVSubstation Automation System(SAS)
GWZC-9000 20kV & 33kV Substation Automation System (SAS)

The GWZC-9000 20kV & 33kV Substation Automation System (SAS) integrates intelligent protection relays, PLCs, and RTUs to automate critical functions like circuit breaker control, fault detection, load management, and power quality monitoring. Compliant with IEC 61850, it enables seamless grid communication while SCADA and HMI provide centralized monitoring and control. The system features advanced protection schemes (overcurrent, earth fault, differential protection), predictive maintenance alerts, and robust cybersecurity to ensure secure data transmission. Ideal for industrial plants, utilities, and commercial facilities, the SAS enhances operational efficiency, minimizes downtime, and supports smart grid integration through real-time data acquisition, remote operation, and rapid fault isolation.

Product Introduction Technical Parameter Size

 Substation Automation System (SAS) Overview​

          The GWZC-9000 ​20kV & 33kV Substation Automation System (SAS)​​ is a ​smart control solution​ that enhances ​medium-voltage power distribution​ by automating monitoring, protection, and switching operations. It is widely used in ​industrial, utility, and renewable energy applications​ to improve ​grid reliability, safety, and efficiency.

​Key Functions of SAS​

  1. ​Remote switching & control​ of circuit breakers and isolators
  2. ​Real-time fault detection & isolation​ to prevent cascading failures
  3. ​Load balancing & power quality monitoring​
  4. ​Event logging & alarm management​ for quick diagnostics
  5. ​Integration with SCADA & EMS​ for grid optimization

Benefits & Role of SAS​

  1. ​Enhanced safety​ by reducing manual switching risks
  2. ​Improved reliability​ with faster fault response
  3. ​Lower operational costs​ through remote monitoring
  4. ​Smart grid compatibility​ for future-ready infrastructure
  5. ​Supports renewable energy integration​

Major Components of SAS​

  1. ​Intelligent Electronic Devices (IEDs)​​ – Protection relays, meters, controllers
  2. SCADA & HMI​ – Centralized control interface
  3. Communication Networks​ – Fiber optics, Ethernet, IEC 61850
  4. Automated Switchgear​ – Circuit breakers, disconnectors
  5. Sensors & RTUs​ – Real-time data collection

This ​integrated automation system​ ensures ​efficient, secure, and resilient power distribution​ for modern electrical networks.

Related products More
GWZC-9581 Low-voltage generator protection relay
GWZC-9586 Low-voltage generator protection relay
detail
GWZC-9506 Cable insulation monitoring device (IMD)​​(ANSI 64)
GWZC-9506 Cable insulation monitoring device
detail
GOWE-9000 Partial discharge online monitoring system
Partial discharge online monitoring system
detail
GOWE-9000 Wireless Temperature Monitoring System for Substations
detail
GWZC-9000 Sewage Treatment Automation Control System
GWZC-9000 Sewage Treatment Automation Control System
detail
Technical Knowledge More
Transformer Protection Relay Panel
Renovation Scheme for Unattended Automatic System of Hydropower Station
The core of the transformation of the unattended automation system for hydropower stations is to upgrade the traditional manually attended power station into a modern intelligent power station with "unattended operation and minimal personnel on duty" through computerized monitoring, intelligent sensing, reliable communication and remote centralized control. It realizes remote monitoring, automatic control, fault self-diagnosis and safety early warning, greatly reducing labor costs and improving operational efficiency and safety. Among them, the secondary electrical system, as the "nervous system, brain and safety line of defense" of the power station, is the core support for the unattended transformation. Without a reliable secondary system, true unattended operation cannot be achieved. Therefore, this integration will focus on improving the detailed content of secondary electrical equipment while retaining the full process details of the transformation.
2026/04/21
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
GWZC-9000 20kV&33kVSubstation Automation System(SAS)