Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Main Transformer On-load Tap Changer Control Relay Side View
Transformer Protection Configuration Principles
Transformer protection is critical for maintaining power system reliability. A well-designed ​transformer protection configuration​ must balance speed, selectivity, and sensitivity to prevent equipment damage and outages. ​Primary protection​ (e.g., differential and gas protection) acts instantly for internal faults, while ​backup protection​ (e.g., overcurrent, zero-sequence) provides redundancy for extended coverage. This guide covers key principles, settings, and coordination to optimize ​transformer protection​ schemes for different transformer types and voltage levels.
2025/08/11
Generator-Transformer Differential Protection Relay Rear View
What Are Positive Sequence, Negative Sequence, and Zero Sequence in Three-Phase Circuits?
In relay protection systems, we often encounter concepts such as zero-sequence current protection in microprocessor-based protection devices and inverse-time negative-sequence protection in transformer protection devices. Initially, I found these concepts quite confusing. However, to facilitate subsequent study and work, it is essential to understand these critical concepts of positive sequence, negative sequence, and zero sequence in three-phase circuits.
2025/08/08
Gas-Insulated Switchgear (GIS)
Gas-Insulated Switchgear (GIS) for High-Altitude Applications
For Gas-Insulated Switchgear (GIS), since the main live circuits are enclosed within sealed, gas-filled compartments and external connections utilize solid insulation, the insulation performance is unaffected by atmospheric pressure. The primary consideration for GIS at high altitudes is the mechanical strength of the gas enclosure (gas compartment).
2025/08/08
switchgear
What are the differences between IEC-standard switchgear and UL-standard switchgear?
IEC standard switchgear and UL standard switchgear (represented by UL1558 and UL891) fall under different technical systems in power systems, with differences mainly reflected in their standard frameworks, structural design, performance requirements, and applicable scenarios. The following is a comprehensive comparative analysis:
2025/08/08
Ring Main Unit
Technical Requirements and Specifications for 17.5kV Ring Main Units in the Saudi National Grid
SEC Specifications: 17.5kV Ring Main Unit (RMU) - Key Features         Outdoor Enclosure: Designed for outdoor installation.         Dedicated Cable Withstand Voltage Test Terminal Compartment: Features a separate, accessible compartment for cable high-potential (Hi-Pot) testing.         Self-Powered Protection Unit: Utilizes an internal power source for the protection relay.         SF6 Insulated, Single-Tank Design F+F+V Configuration: Common SF6 gas tank housing a combination of Load Switch (F) + Load Switch (F) + Circuit Breaker (V).         Ratings: Ring Switch Unit: 630A. Feeder Circuit Breaker: 200A.         Compliance Standard: SEC Standard 32-SDMS-11.
2025/08/08
Medium Voltage Switchgear
Medium Voltage Switchgear UL Standard Specifications
Switchgear destined for the North American market requires UL (Underwriters Laboratories) certification. UL is a U.S. safety certification organization. It develops its own standards, such as UL 891 (Dead-Front Distribution Switchboards), UL 67 (Panelboards), and UL 845 (Motor Control Centers), and also provides product certification services.
2025/08/07
Generator-Protection-Panel
What protection relays are required for hydroelectric power stations ?
  Note: ANSI/IEEE device numbers (e.g., 87G, 50BF) and standardized terminology are maintained throughout. Hydro-specific protections align with IEEE Std 125-2021 and IEC 60545 guidelines. Our company specializes in manufacturing protection relays for hydroelectric power stations. We distribute products globally and provide one-stop solutions for hydroelectric power station automation systems. Consult us online today!
2025/08/05
1234...6
PRODUCT NAVIGATION
news
GWZC-9000 Drainage Pumping Station Automation System
Drainage Pumping Station Automation System—Forging a New Urban Flood Control Ecosystem
Drainage pump stations employ electromechanical systems for active water discharge, IoT and AI for precise regulation, and backup power for reliability. Digital twin platforms optimize decision-making with failure prediction and damage assessment. Each ¥100M investment reduces annual losses by ¥230M while saving 30% energy, as proven by Tokyo's flood defense system.
2025/07/23
Hydropower Station
Comprehensive Analysis of the Yarlung Zangbo River Hydropower Station
Massive hydropower potential, extreme seismic/geological challenges, unprecedented engineering (tunnels, dam, turbines), sensitive ecology, and critical transboundary impacts.​
2025/07/22
VT (Voltage Transformer ) Protection RelayRear View
Comprehensive Protection Relay: Full Analysis​
A comprehensive protection relay is an intelligent device that safeguards electrical systems by detecting faults (e.g., overcurrent, short circuits) and isolating affected equipment. It integrates multiple protection functions, ensures system reliability, and prevents damage. This guide covers its definition, working principle, protection targets, activation conditions, and outcomes.
2025/07/18
Marine Switchboard
Marine Switchboard Market Share Analysis and Development Trend Analysis
Conclusion: European players maintain short-term dominance in premium segments, but Chinese manufacturers are rapidly gaining ground through cost and scale advantages. Future competition will center on smart functionalities, green compatibility, and modular innovation, with technological agility determining market repositioning.
2025/07/17