GWZC-9887 Generator-Transformer Differential Protection Relay
details
GWZC-9887 Generator-Transformer Differential Protection Relay (87G|87T)

Product Overview: GWZC-9887 Generator-Transformer Differential Protection Relay provides complete differential protection for generator-transformer units. Features percentage differential protection, harmonic restraint, and IEC61850 communication support. Installs in switchgear panels for medium-small generator-transformer protection.

Product functions(ANSI):87H | 87 | 87A | 87B | 71M | 71T | 38 | 49 | 71O | 63PR | 27/81U | 40

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9621 Distribution transformer protection relay
details
GWZC-9621 Distribution transformer protection relay

Product Overview : GWZC-9621 GWZC-9621​ Distribution transformer protection relay safeguards ≤1600kVA station/grounding transformers (≤35kV) with integrated monitoring, designed for LV switchgear.

Product functions(ANSI):50/51/27 | 51 | 46 | 50G/51G | 49 | 59 | 27 | 74

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9829 Main Transformer On-load Tap Changer Control Relay
details
GWZC-9829 Main Transformer On-load Tap Changer Control Relay

Product Overview : The GWZC-9829 relay provides on-load tap changer control for 66kV/110kVpower transformers, enabling tap position monitoring and voltage regulation.

Product functions(ANSI):94 | 90

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9828 Transformer Non-Electrical Protection Relay
details
GWZC-9828 Transformer Non-Electrical Protection Relay

Product Overview : Transformer Non-Electrical Protection Relay​ monitors oil temperature, gas, and pressure in transformers (35kV+). Installed on transformers or in control cabinets, it provides alarms/trips to prevent failures. Essential for substations and power plants, it complements electrical protection systems.

Product functions(ANSI):71G | 26/49 | 63 | 38

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9827 Transformer Backup Protection Relay
details
GWZC-9827 Transformer Backup Protection Relay

Product Overview : GWZC-9827​ is a transformer backup protection relay for 66kV/33kV/11kV systems, providing overcurrent, earth fault and overload protection. Installed in switchgear, it offers secondary protection with IEC 61850/Modbus support.

Product functions(ANSI):50/51 | 51 | 50N/51N | 51N | 49 | 50G/51G | 38/74 | 59 | 59N | 27 | 74 | 60 | 27/81U | 27/81L | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9821C Transformer Differential Protection Relay
details
GWZC-9821C Transformer Differential Protection Relay (87H | 87 | 87AL)

Product Overview: The ​GWZC-9821C​ is a transformer differential relay that detects internal faults while preventing inrush false trips. Installed in substation panels, it provides reliable protection for power transformers in utility/industrial systems.

Product functions(ANSI):87H | 87 | 87AL | 50/51 | 51V | 49 | 46 | 46 | 50N/51N | 51N | 59 | 27 | 59N | 60FL | 60 | 60CT | 74 | 27D | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9821 Transformer protection relay
details
GWZC-9821 Transformer protection relay

Product Overview : GWZC-9821 Transformer Protection Relay Specifically designed for power transformers, this device is installed in switchgear cabinets of substations and industrial power distribution systems to ensure safe and reliable operation of transformers.
Product functions(ANSI):51P/27 | 51I | 51N | 49 | 46 | 59/27/59N
Communication functions :​​ IEC61850 | IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my