GWZC-9887 Generator-Transformer Differential Protection Relay
details
GWZC-9887 Generator-Transformer Differential Protection Relay (87G|87T)

Product Overview: GWZC-9887 Generator-Transformer Differential Protection Relay provides complete differential protection for generator-transformer units. Features percentage differential protection, harmonic restraint, and IEC61850 communication support. Installs in switchgear panels for medium-small generator-transformer protection.

Product functions(ANSI):87H | 87 | 87A | 87B | 71M | 71T | 38 | 49 | 71O | 63PR | 27/81U | 40

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9621 Distribution transformer protection relay
details
GWZC-9621 Distribution transformer protection relay

Product Overview : GWZC-9621 GWZC-9621​ Distribution transformer protection relay safeguards ≤1600kVA station/grounding transformers (≤35kV) with integrated monitoring, designed for LV switchgear.

Product functions(ANSI):50/51/27 | 51 | 46 | 50G/51G | 49 | 59 | 27 | 74

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9829 Main Transformer On-load Tap Changer Control Relay
details
GWZC-9829 Main Transformer On-load Tap Changer Control Relay

Product Overview : The GWZC-9829 relay provides on-load tap changer control for 66kV/110kVpower transformers, enabling tap position monitoring and voltage regulation.

Product functions(ANSI):94 | 90

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9828 Transformer Non-Electrical Protection Relay
details
GWZC-9828 Transformer Non-Electrical Protection Relay

Product Overview : Transformer Non-Electrical Protection Relay​ monitors oil temperature, gas, and pressure in transformers (35kV+). Installed on transformers or in control cabinets, it provides alarms/trips to prevent failures. Essential for substations and power plants, it complements electrical protection systems.

Product functions(ANSI):71G | 26/49 | 63 | 38

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9827 Transformer Backup Protection Relay
details
GWZC-9827 Transformer Backup Protection Relay

Product Overview : GWZC-9827​ is a transformer backup protection relay for 66kV/33kV/11kV systems, providing overcurrent, earth fault and overload protection. Installed in switchgear, it offers secondary protection with IEC 61850/Modbus support.

Product functions(ANSI):50/51 | 51 | 50N/51N | 51N | 49 | 50G/51G | 38/74 | 59 | 59N | 27 | 74 | 60 | 27/81U | 27/81L | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9821C Transformer Differential Protection Relay
details
GWZC-9821C Transformer Differential Protection Relay (87T)

Product Overview: The ​GWZC-9821C​ is a transformer differential relay that detects internal faults while preventing inrush false trips. Installed in substation panels, it provides reliable protection for power transformers in utility/industrial systems.

Product functions(ANSI):87T | 87 | 87AL | 50/51 | 51V | 49 | 46 | 46 | 50N/51N | 51N | 59 | 27 | 59N | 60FL | 60 | 60CT | 74 | 27D | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9821 Transformer protection relay
details
GWZC-9821 Transformer protection relay

Product Overview : GWZC-9821 Transformer Protection Relay Specifically designed for power transformers, this device is installed in switchgear cabinets of substations and industrial power distribution systems to ensure safe and reliable operation of transformers.
Product functions(ANSI):51P/27 | 51I | 51N | 49 | 46 | 59/27/59N
Communication functions :​​ IEC61850 | IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Main Transformer-Protection Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.
2025/11/24
Transformer protection relay
Transformer Differential Protection(ANSI 87T): Working Principle, Function, and Setting Calculation
The working principle of the Transformer Differential Protection Relay is based on Kirchhoff's Current Law. This law states that the sum of currents entering a node is zero. Ideally, for a healthy (non-faulted) transformer, the current entering the primary winding should equal the current leaving the secondary winding (after accounting for the transformer's turns ratio and phase shift).
2025/11/12
Main Transformer On-load Tap Changer Control Relay Side View
Transformer Protection Configuration Principles
Transformer protection is critical for maintaining power system reliability. A well-designed ​transformer protection configuration​ must balance speed, selectivity, and sensitivity to prevent equipment damage and outages. ​Primary protection​ (e.g., differential and gas protection) acts instantly for internal faults, while ​backup protection​ (e.g., overcurrent, zero-sequence) provides redundancy for extended coverage. This guide covers key principles, settings, and coordination to optimize ​transformer protection​ schemes for different transformer types and voltage levels.