Power system stability control device related product

GWZC-9602 Anti-islanding protection relay
details
GWZC-9602 Anti-islanding protection relay(AIP)

Product Overview : GWZC-9602 Anti-islanding Protection Relay is designed for distributed generation systems, providing comprehensive protection, measurement, and control functions at grid interconnection points. It effectively prevents islanding conditions and ensures safe operation of distributed power sources.

Product functions(ANSI):81O| 81U| 59| 27| 81R | 32 | 94 | 67 | 50N/51N | 59N | 79 | 60FL | 50H/51H

Communication functions : IEC61850 |IEC 60870-5-103 |MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9603 Reverse Power Protection Relay
details
GWZC-9603 Reverse Power Protection Relay (ANSI 32)

Product Overview : The ​GWZC-9603​ reverse power relay detects and blocks reverse power flow in 6.6kV-33kV systems, with adjustable trip settings for generator and grid protection in switchgear applications.

Product functions(ANSI):50 | 51 | 49 | 50N/51N | 32 | 32R | 79 | 59 | 27 | 59N | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9601 Fault Islanding Protection Device
details
GWZC-9601 Fault Islanding Protection Device

Product Overview : GWZC-9601​ is a fault disconnection relay for ​10-35kV grids, detecting and isolating faults (overcurrent, undervoltage, frequency issues) to prevent system failures.

Product functions(ANSI):59N | 27 | 59 | 81U | 81O | 78 | 60 | 94

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9694 Low-Frequency Low-Voltage Load Shedding Device
details
GWZC-9694 Low-Frequency Low-Voltage Load Shedding Device

Product Overview : GWZC-9694Underfrequency/Undervoltage Load Shedding (UFUVLS) device is a grid protection system that automatically cuts loads to maintain stability during frequency drops or voltage dips, preventing blackouts in renewable-rich power networks.

Product functions(ANSI):27L1, 27L2, 27L3 | 59L1, 59L2, 59L3 | 81L1, 81L2, 81L3 | ​81O1, 81O2, 81O3

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Transformer Protection Relay Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.