GWZC-9000 Busbar Protection Panel
details
GWZC-9000 Busbar Protection Panel

Product Overview: GWZC-9000 Busbar Protection Panel provides comprehensive protection for electrical busbars against various faults, ensuring system stability. Features differential protection function, configurable settings, and support for Modbus RTU, IEC61850(Optional). Installs in substation control rooms for power system busbar protection in transmission and distribution networks.

Product functions(ANSI):87 | 50BF | 50BF | 50 | 60 | 60 | 60 | 50 | 27
Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 3× Ethernet Ports | 3× RS-485

details
GWZC-9000 Fault recorder panel (​FRP) (ANSI 21)

Introduction : The Fault Recorder Panel (FRP) serves as the “black box” of power systems, capturing real-time voltage/current waveforms and digital signals during faults to provide critical data for fault analysis and protection verification. ​(ANSI 21)

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

GWZC-9000 Power measurement and control panel
details
GWZC-9000 Power measurement and control panel

Application Scope : The Power Measurement and Control Panel is a key substation automation device. It monitors and controls auxiliary equipment (like DC systems, station power, fire protection), featuring data acquisition, communication, alarms, and IEC 61850-compliant remote control.

Product functions(ANSI):60 | 59N | 25 | 59 | 50/51 | 50N/51N | 94

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

Low-voltage load shedding panel
details
GWZC-9000 Low-voltage load shedding panel

Application Scope : The GWZC-9000 low-frequency and low-voltage load shedding panel is a critical protection device in power systems. It automatically sheds non-essential loads according to preset sequences when system frequency or voltage abnormally drops, preventing system collapse.

Product functions(ANSI):827 | 59 | 81U | 81O | 60

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

RTU Communication Panel
details
GWZC-9000 Remote Terminal Unit (RTU) Communication Panel

Application:Used in PV plants, substations, power plants, and power automation systems for protocol conversion, data acquisition, and transmission.
Protocol Conversion: Supports mutual conversion and uplink of Modbus, IEC 103/104, IEC 61850, and TCP/IP.
Data Handling: Acquires data from protection relays/power meters, converts it to SCADA/dispatch-compliant protocols, and transmits to master stations/dispatch systems.

Main Transformer Protection Panel
details
GWZC-9000 Main Transformer Protection Panel

Application Scope : The GWZC-9000 main transformer protection control panel is designed for the protection and control of medium to large capacity main transformers with voltage levels of 11kV, 33kV, 69kV, 115kV,132.

Product functions(ANSI):87H | 87 | 87A | 60 | 50/51 | 51 | 50N/51N | 51N | 49 | 50G/51G | 38/74 | 59 | 59N | 27 | 74 | 60 | 27/81U | 27/81L | 30 | 71G | 26/49 | 63 | 38

Generator Protection Panel
details
GWZC-9000 Generator protection panel​

Product Overview : The ​GWZC-9000 generator protection panel is mainly used for the control and protection of hydroelectric units, gas turbine units, biogas units, and large diesel generator sets.

Product functions(ANSI):87H | 87 | 87A | 49 | 50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74 | 50N/51N | 50G/51G

Product Components : GWZC-9884 Generator Differential Protection Relay | GWZC-9885 Generator Rotor Earth Fault Protection Relay | GWZC-9886 Generator Backup Protection Relay | Panel and accessories

Technical Knowledge More
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Transformer Protection Relay Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.