Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Numeric protection panel​ related product

details
GWZC-9000 Fault recorder panel (​FRP) (ANSI 21)

Introduction : The Fault Recorder Panel (FRP) serves as the “black box” of power systems, capturing real-time voltage/current waveforms and digital signals during faults to provide critical data for fault analysis and protection verification. ​(ANSI 21)

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

GWZC-9000 Power measurement and control panel
details
GWZC-9000 Power measurement and control panel

Application Scope : The Power Measurement and Control Panel is a key substation automation device. It monitors and controls auxiliary equipment (like DC systems, station power, fire protection), featuring data acquisition, communication, alarms, and IEC 61850-compliant remote control.

Product functions(ANSI):60 | 59N | 25 | 59 | 50/51 | 50N/51N | 94

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

Low-voltage load shedding panel
details
GWZC-9000 Low-voltage load shedding panel

Application Scope : The GWZC-9000 low-frequency and low-voltage load shedding panel is a critical protection device in power systems. It automatically sheds non-essential loads according to preset sequences when system frequency or voltage abnormally drops, preventing system collapse.

Product functions(ANSI):827 | 59 | 81U | 81O | 60

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

RTU Communication Panel
details
GWZC-9000 Remote Terminal Unit (RTU) Communication Panel

Application:Used in PV plants, substations, power plants, and power automation systems for protocol conversion, data acquisition, and transmission.
Protocol Conversion: Supports mutual conversion and uplink of Modbus, IEC 103/104, IEC 61850, and TCP/IP.
Data Handling: Acquires data from protection relays/power meters, converts it to SCADA/dispatch-compliant protocols, and transmits to master stations/dispatch systems.

Main Transformer Protection Panel
details
GWZC-9000 Main Transformer Protection Panel

Application Scope : The GWZC-9000 main transformer protection control panel is designed for the protection and control of medium to large capacity main transformers with voltage levels of 11kV, 33kV, 69kV, 115kV,132.

Product functions(ANSI):87H | 87 | 87A | 60 | 50/51 | 51 | 50N/51N | 51N | 49 | 50G/51G | 38/74 | 59 | 59N | 27 | 74 | 60 | 27/81U | 27/81L | 30 | 71G | 26/49 | 63 | 38

Generator Protection Panel
details
GWZC-9000 Generator protection panel​

Product Overview : The ​GWZC-9000 generator protection panel is mainly used for the control and protection of hydroelectric units, gas turbine units, biogas units, and large diesel generator sets.

Product functions(ANSI):87H | 87 | 87A | 49 | 50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74 | 50N/51N | 50G/51G

Product Components : GWZC-9884 Generator Differential Protection Relay | GWZC-9885 Generator Rotor Earth Fault Protection Relay | GWZC-9886 Generator Backup Protection Relay | Panel and accessories

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my