One-Sentence Summary:High-voltage fire-resistant switchgear is designed for electrical systems rated up to 10kV, providing fire-resistant power distribution, protection, and control in high-fire-risk installations such as substations, industrial plants, and high-rise buildings.

Rated Voltage: 7.2kV, 12kV, 24kV (per IEC 62271-1)
Rated Current: 630A, 1250A, 2500A, 3150A
Rated Short-Circuit Breaking Current: 20kA, 25kA, 31.5kA, 40kA (compliant with IEC 62271-100)
Insulation Level:Power Frequency Withstand Voltage: 42kV/1min (for 12kV switchgear)/Lightning Impulse Withstand Voltage: 75kV (for 12kV switchgear)
Ingress Protection (IP): IP4X (enclosure) / IP2X (operating front) (IEC 60529)
Fire Resistance Rating: ≥1 hour (passing IEC 60695 fire resistance tests)

Product Introduction Technical Parameter Size

1.Product Overview
        High-voltage fire-resistant switchgear is a metal-enclosed assembly engineered for high-fire-risk environments, featuring a vacuum circuit breaker + solid-insulated busbar core. The enclosure is constructed from welded aluminum-zinc steel plates, with internal compartments sealed using metal barriers + fire-resistant fillers. Compliant with IEC 62271-200 for “Arc Fault Level Rating” (AFLR), it maintains structural integrity during internal arcing faults through directional pressure venting. Halogen-free flame-retardant materials suppress toxic gas emissions, ensuring safe evacuation.

2.Primary Functions
        Power Distribution: Enables multi-circuit power control and allocation.
        Short-Circuit/Overload Protection: Rapid fault current interruption via circuit breakers.
        Fire Containment: Fire-resistant barriers (ceramifiable silicone/mica plates) and arc-quenching gases.
        Condition Monitoring: Integrated interfaces for temperature, arcing, and partial discharge monitoring (IEC 61850 communication).
        Five-Safety Interlocking: Mechanical interlocks to prevent misoperation (IEC 62271-200).
        Fault Isolation: Directional pressure relief channels for arc-fault events (IEC 62271-200 Annex AA).

3.Product Parameters (Detailed)
        Electrical Parameters:Rated Voltage: 12kV; 1min Power Frequency Withstand: 42kV (IEC 62271-1),Rated Short-Time Withstand Current: 31.5kA/4s (IEC 62271-100)
        Mechanical Endurance:Circuit Breaker: 10,000 operations; Disconnector: 3,000 operations (IEC 62271-100)
        Environmental Compliance:Operating Temperature: -25°C to +40°C; Humidity ≤95% (IEC 60068-2)
        Fire Performance:Fire Resistance Duration: ≥60min (950°C flame) (IEC 60695-2-11)/Flame Retardancy Class: V-0 (Internal materials) (UL 94)
        Smart Features:Supports temperature sensors, arc-flash protection, and partial discharge monitoring (IEC 61850 Ed.2.0)

4.Product Features
Multi-Layer Fire Protection:
        Compartments use ceramifiable fireproof putty + double-layer steel plates, maintaining integrity at 950°C for ≥60min.
        Busbar chambers filled with N₂/SF₆ hybrid gas to suppress arc reignition.

Enhanced Safety Design:
        Certified for Internal Arc Fault (IAC AFLR 31.5kA/1s) with roof-directed pressure vents.
        Mechanical interlock between earthing switch and circuit breaker prevents live grounding.

Eco-Efficiency:
        Vacuum interrupters generate zero greenhouse gases; RoHS-compliant materials.

Smart Maintenance:
        Integrated wireless temperature sensors (±1°C accuracy) enabling Condition-Based Monitoring (CBM).

Compact Modularity:
        Expandable busbar system; ≤1.5mm/m alignment tolerance for cubicle extensions.
        International Standards Compliance:
        Insulation Design: IEC 62271-1
        Arc Fault Protection: IEC 62271-200 Annex AA
        Fire Testing: IEC 60695-2-11
        Communication Protocol: IEC 61850-7-420

medium and high voltage fire-resistant switchgear Models and Dimensions
        Typical Models: KYN28A-12(Z), UniGear ZS1 (Schneider), 8DJH (Siemens)
        Standard Dimensions (W × D × H):
        Circuit Breaker Compartment: 800mm × 1500mm × 2300mm
        VT/Metering Compartment: 600mm × 1500mm × 2300mm
        Busbar Connection Compartment: 600mm × 1500mm × 2300mm

Related products More
FZN25-12 series load switchgear
FZN25-12 series load switchgear
detail
KYN61-40.5 withdrawable AC metal-enclosed high-voltage switchgear
detail
XGN17-40.5 fixed-type high-voltage switchgear
XGN17-40.5 fixed-type high-voltage switchgear
detail
High Voltage Shore Connection Cabinet
detail
Marine Medium/High Voltage Switchboard
Marine Medium/High Voltage Switchboard
detail
technical knowledge More
Gas-Insulated Switchgear (GIS)
Gas-Insulated Switchgear (GIS) for High-Altitude Applications
For Gas-Insulated Switchgear (GIS), since the main live circuits are enclosed within sealed, gas-filled compartments and external connections utilize solid insulation, the insulation performance is unaffected by atmospheric pressure. The primary consideration for GIS at high altitudes is the mechanical strength of the gas enclosure (gas compartment).
2025/08/08
switchgear
What are the differences between IEC-standard switchgear and UL-standard switchgear?
IEC standard switchgear and UL standard switchgear (represented by UL1558 and UL891) fall under different technical systems in power systems, with differences mainly reflected in their standard frameworks, structural design, performance requirements, and applicable scenarios. The following is a comprehensive comparative analysis:
2025/08/08
Ring Main Unit
Technical Requirements and Specifications for 17.5kV Ring Main Units in the Saudi National Grid
SEC Specifications: 17.5kV Ring Main Unit (RMU) - Key Features         Outdoor Enclosure: Designed for outdoor installation.         Dedicated Cable Withstand Voltage Test Terminal Compartment: Features a separate, accessible compartment for cable high-potential (Hi-Pot) testing.         Self-Powered Protection Unit: Utilizes an internal power source for the protection relay.         SF6 Insulated, Single-Tank Design F+F+V Configuration: Common SF6 gas tank housing a combination of Load Switch (F) + Load Switch (F) + Circuit Breaker (V).         Ratings: Ring Switch Unit: 630A. Feeder Circuit Breaker: 200A.         Compliance Standard: SEC Standard 32-SDMS-11.
2025/08/08
Medium-High Voltage Fire-Resistant Switchgear
Inquiry Consultation
产品表单
Inquiry Consultation
+86-13655813785
+86-13655813785
+86-13655813785
+86-13655813785
home product email
live chat
my