Product Overview: 15KV-10KV Medium Voltage (MV) Outgoing Feeder Switchgear is a critical component in power distribution systems for controlling, protecting, and isolating electrical circuits at voltage levels up to 15KV (including 12KV/11KV/10KV). Designed to comply with IEC 62271 standards, these metal-enclosed switchgear assemblies are widely used in industrial, commercial, and utility networks. Key components include circuit breakers, disconnectors, protection relays, and advanced monitoring systems, offering high safety and modular configurability.
Rated Voltage : 10KV/11KV/12KV/15KV
Rated Current : 630A/1250A/1600A/2000A/2500A
Short-Circuit Breaking Capacity : 20KA/25KA/31.5KA/40KA
IP Rating : IP4X (Enclosure)/IP2X (Front Panel)
Insulation Medium : Air Insulation/SF6 Gas Insulation
Operating Mechanism : Spring-Charged/Motorized/Manua
Common Chinese Models:KYN28-12;XGN15-12;HXGN-10;MNS-12
1. Product Description
15KV/11KV/10KV Outgoing Feeder Switchgear serves as the backbone of power distribution systems, featuring either fixed or withdrawable designs. The enclosure is constructed from cold-rolled steel plates with compartmentalization meeting “Five-Prevention Interlock” requirements (e.g., preventing circuit breaker operation under load).
Main busbars utilize copper conductors with epoxy resin or SMC insulation, ensuring dielectric strength. Typical applications include:
10-15KV substation outgoing feeders
Industrial plant power distribution
Renewable energy grid interconnection
Data center dual-source transfer
Certified through type tests (TTA) and internal arc fault tests (IAC AFLR Class), the equipment guarantees reliable operation under extreme conditions.
2. Product Functions
Power Distribution: Busbar systems enable multi-circuit power routing (single/double bus configurations).
Protection: Integrated overcurrent, instantaneous trip, and earth fault protection with digital relays.
Monitoring: Optional sensors for real-time temperature, partial discharge, and mechanical state tracking.
Isolation: Visible break disconnectors with mechanical interlocks for maintenance safety.
Communication: IEC 61850 protocol support for SCADA integration.
Advanced options:
Arc flash detection system
Wireless temperature monitoring
Fault waveform recording
3. Standard & Optional Configurations
Standard:
Vacuum circuit breaker (VS1/ZN63 series)
Current transformers (0.2S/5P20 class)
Voltage transformers (JDZ10 type)
Surge arresters (HY5WZ ZnO type)
Voltage presence indicators (DXN-Q type)
Optional:
Intelligent control unit (with voice prompts)
Condensation prevention heaters
SF6 gas density monitors (for gas-insulated units)
Automatic transfer switches (ATS)
4. Key Features
Safety:
Passed 40kA/4s short-circuit withstand tests
Pressure relief flaps for internal arc fault mitigation
Reliability:
Circuit breaker mechanical endurance ≥10,000 operations
Main circuit contact resistance ≤50μΩ
Smart Grid Ready:
Modbus RTU/DNP3.0 protocol support
RFID-based contact temperature telemetry
Eco-Friendly:
SF6-free alternatives (dry air insulation available)
90% recyclable steel content
15kV-10kV outgoing switchgear Technical Specifications