GWZC-9631 Motor Protection Relay
details
GWZC-9631 Motor Protection Relay

Product Overview : GWZC-9631 Motor Protection Relay​ safeguards asynchronous motors (≤1600kW) against overload, short-circuit, and voltage/phase faults. Features motor control, monitoring, and Modbus communication. Installs in MCCs for industrial applications like pumps and compressors.

Product functions(ANSI):50 | 51 | 46 | 46 | 49 | 48 | 50N/51N | 27 | 49 | 99 | 86 | 90

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9833 Motor Magnetic Balance Differential Protection Relay
details
GWZC-9833 Motor Magnetic Balance Differential Protection Relay (87M)

Product Overview : GWZC-9833​ provides magnetic balance differential protection for HV motors, with overcurrent and thermal protection. Installed in motor control centers, it safeguards critical industrial motors with fault recording capability.

Product functions(ANSI):87M | 50 | 51 | 51 | 51 | 49 | 48 | 50Q | 46 | 46 | 50N/51N | 49 | 48 | 86 | 59 | 27 | 59N | 81O | 81U | 60FL | 27 | 74 | 27/81U | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9832 Motor Differential Protection Relay GWZC-983
details
GWZC-9832 Motor Differential Protection Relay (87M)

Product Overview : GWZC-9832 Motor Differential Protection Relay for HV/LV motors (11kV-400V), detecting internal faults with CT supervision. Installed in MCCs and switchgear for fast fault clearance in industrial/power applications.

Product functions(ANSI):87H | 87 | 50 | 51 | 51 | 51V | 49 | 48 | 46 | 46 | 46V | 50N/51N | 49 | 48 | 86 | 59 | 27 | 59N | 81O | 81U | 60FL | 60 | 74 | 27/81U | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9831 Motor protection relay
details
GWZC-9831 Motor protection relay

Product Overview : GWZC-9831 Motor Protection Relay Designed specifically for 0.4kV and 10kV motor protection applications, this relay enhances motor reliability, safety, and automation levels in industrial and power distribution systems.
Product functions(ANSI):50/51 | 49 | 48 | 46 (Stage I) | 51N/50N | 48LR | 66 | 59 | 27 | 59N | 81O | 81U | 60FL | 27X | 74 | 50BF | 38 | 49T
Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my