Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Line protection relay related product

GWZC-9812 Distance protection relay
details
GWZC-9612 Distance protection relay(21 | 21G | 21FL)

Product Overview : The ​GWZC-9612 Distance Protection Relay​ provides directional line protection (distance, current, voltage) and three-phase auto-reclosing for distribution systems below 35kV.

Product functions(ANSI):21 | 21G | 21FL | 68 | 50/51 | 50N/51N | 32 | 27 | 79 | 50HS/79 | 49 | 81U | 60FL

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9511 Feeder Protection Relay
details
GWZC-9511 Feeder Protection Relay

Product Overview : GWZC-9511 Feeder Protection Relay​ Protects, controls (auto-reclosing), and monitors ​MV distribution feeders (11kV-33kV)​. Installed in ​substation/industrial feeder switchgear​ to safeguard outgoing circuits.

Product functions(ANSI):50 | 51 | 50N | 51N | 49 | 79 | 50 | 81U | 27 | 64

Communication functions : IEC61850(Optional) | ​​IEC 60870-5-103 | MODBUS RTU | 1× Ethernet Ports | 1× RS-485

GWZC-9613 FO Line Diff Relay(87L)
details
GWZC-9613 FO Line Diff Relay(87L)

Product Overview : This FO Line Diff Relay protects 132kV and below transmission lines in ungrounded/low-resistance systems, offering primary/backup protection with monitoring. Supports switchgear/panel mounting via fiber channels with E1 interface.

Product functions(ANSI):87L |50/51 | 51 |50N/51N | 51N | 81U | 49 | 79 | 60 | 60 | 60 | 60/51 | 94 |21

Communication functions : IEC61850 | IEC 60870-5-103 |MODBUS RTU |2× Ethernet Ports | 2× RS-485

GWZC-9614Bus differential protection relay
details
GWZC-9614 Bus differential protection relay

Product Overview : GWZC-9614 Bus Differential Protection Relay Applicable for voltage levels up to 132kV, supporting various busbar configurations including single bus, sectionalized single bus, triple-section single bus, double bus, double bus with single section, and double bus with double sections.

Product functions(ANSI):87 | 50BF | 50BF | 50 | 60 | 60 | 60 | 50 | 27

Communication functions : IEC61850 |​​IEC 60870-5-103 |MODBUS RTU |3× Ethernet Ports |3× RS-485

GWZC-9611C Line differential protection relay
details
GWZC-9611C Line differential protection relay (87H | 87)

Product Overview : The GWZC-9611C line differential protection relay is specifically designed for power distribution systems up to 66kV, featuring pilot-wire differential protection technology for fast fault clearance.

Product functions(ANSI):87H | 87 | 87A | 50 | 51 | 51V | 49 | 46 | 50N/50G | 59 | 27 | 81 | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9611  Line protection relay
details
GWZC-9611 Line protection relay

Product Overview : GWZC-9611 Line Protection Relay is designed for the protection of 33kV & 66kV transmission lines and feeder circuits, featuring easy installation and simple commissioning.
Product functions(ANSI):51P/27 | 51I | 51N | 49 | 46 | 59/27/59N
Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Transformer Protection Relay Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.
2025/11/24
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my