Applicable Scope :The ​GWZC-9000 generator protection panel is primarily designed for the control and protection of hydroelectric units, gas turbine units, biogas units, and large diesel generator sets. Integrating protection, measurement, and communication functions, it enables comprehensive protection and control of various generator units, facilitating reduced or unattended operation.

Product functions(ANSI):87H | 87 | 87A | 49 | 50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74 | 50N/51N | 50G/51G

Communication protocols : ​IEC 60870-5-101/103/104 ,IEC 61850(MMS/GOOSE/SV), Modbus RTU​ & ​Modbus TCP​,RJ-45 , RS-485

Product Introduction Technical Parameter Size

Generator Protection Panel Overview

          The generator protection panel integrates generator protection devices within a centralized control cabinet. It serves to control and protect high/low-voltage systems, generator sets, paralleling cabinets, and grid-tie cabinets.
Key components include:
          GWZC-9884 Generator Differential Protection Relay
          GWZC-9885 Generator Rotor Earth Fault Protection Relay
          GWZC-9886 Generator Backup Protection Relay
          Generator Measurement and Control Device
          Cabinets (2260 * 800 * 600 or Customizable) with accessories

Generator Protection Panel Functions (ANSI) :

          GWZC-9884 Generator Differential Protection Relay : Detects internal stator winding short circuits by comparing current differences at both ends of the generator, enabling rapid fault clearance (Core principle: Kirchhoff’s Current Law).(87H | 87 | 87A )

          GWZC-9885 Generator Rotor Earth Fault Protection Relay: Identifies insulation failures to ground in stator or rotor windings to prevent leakage currents or arc hazards (Utilizing fundamental/3rd harmonic principles, etc.). (50N/51N)

          GWZC-9886 Generator Backup Protection Relay: Acts as a secondary defense when primary protection fails or fault coverage expands, operating with time delay (e.g., overcurrent, impedance protection).(49 | 50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74 )

          Measurement & Control Device: Monitors real-time parameters like voltage, current, and power while executing remote commands (e.g., synchronization, load adjustment).

Related products More
GWZC-9000 Busbar Protection Panel
GWZC-9000 Busbar Protection Panel
detail
GWZC-9000 Fault recorder panel (​FRP) (ANSI 21)
detail
GWZC-9000 Power measurement and control panel
GWZC-9000 Power measurement and control panel
detail
GWZC-9000 Low-voltage load shedding panel
Low-voltage load shedding panel
detail
GWZC-9000 Remote Terminal Unit (RTU) Communication Panel
RTU Communication Panel
detail
Technical Knowledge More
Wireless Temperature Monitoring System for Substations
Wireless Temperature Monitoring System: Application in Switchgear​
This article introduces the application of wireless temperature monitoring systems in high-voltage and low-voltage switchgear. The configuration of the wireless temperature monitoring system varies across different equipment. If you need a customized wireless temperature monitoring solution for your project, please visit our website for more information.
2025/09/08
GWZC-9804 Arc Flash Protection Relay
Switchgear Arc Flash Protection System Configuration Scheme
This article introduces the configuration scheme for a switchgear arc flash protection system. Busbar arc flash protection monitors the busbar compartment and trips the incoming breaker, while feeder arc flash protection monitors the circuit breaker compartment and cable compartment to trip the feeder breaker. A proper arc flash protection system configuration scheme can effectively protect personnel and equipment safety. For information on a reliable arc flash protection system configuration scheme, please visit our website.
2025/09/04
Arc Flash Protection Relay
Arc Protection Working Principle and Decision Process
Arc Flash Protection is a specialized safety system engineered to rapidly detect and mitigate destructive electrical arc flash faults. Unlike conventional overcurrent protection, it utilizes a combination of light and current sensors to identify an arc flash event within milliseconds. By triggering a circuit breaker to isolate the fault incredibly fast, Arc Flash Protection significantly reduces the explosive energy released, safeguarding personnel from severe injury and preventing extensive damage to electrical equipment like switchgear. This makes it an indispensable defense layer in industrial, commercial, and utility power systems.