Generator protection relay related product

details
GWZC-9586 Low-voltage generator protection relay

Scope of Application: The GWZC-9586 low-voltage generator protection relay is suitable for backup protection of 400V low-voltage generators below 1000kW. It can be installed in panels or locally in switchgear.
Protection Functions(ANSI): 50 | 51 | 50N | 51N | 50I | 50V | 32 | 81U | 80O | 59 | 27
Monitoring and Control Functions: • 14 channels of remote signal input collection; • 8 channels of relay outputs; • Event SOE recording
Communication Functions: 2 Ethernet interfaces (supporting Ethernet 103 protocol, optional); 1 RS485 communication port (supporting Modbus-RTU protocol)

GWZC-9887 Generator-Transformer Differential Protection Relay
details
GWZC-9887 Generator-Transformer Differential Protection Relay (87G|87T)

Product Overview: GWZC-9887 Generator-Transformer Differential Protection Relay provides complete differential protection for generator-transformer units. Features percentage differential protection, harmonic restraint, and IEC61850 communication support. Installs in switchgear panels for medium-small generator-transformer protection.

Product functions(ANSI):87H | 87 | 87A | 87B | 71M | 71T | 38 | 49 | 71O | 63PR | 27/81U | 40

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9886 Generator Backup Protection Relay
details
GWZC-9886 Generator Backup Protection Relay

Product Overview : The ​GWZC-9886​ is a generator backup relay for 10kV–35kV systems, offering overcurrent, under/overvoltage, and reverse power protection. Installed in generator panels, it ensures fault backup security.

Product functions(ANSI):50/51 | 51 | 49 | 46 | 50N/51N | 40 | 32 | 81O/81U | 59/27 | 59N | 64S | 60 | 27 | 27/81U | 74

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9885 Generator Rotor Earth Fault Protection Relay
details
GWZC-9885 Generator Rotor Earth Fault Protection Relay

Product Overview : GWZC-9885 Rotor Earth Fault Relay​ – Provides two-stage protection (alarm/trip) with insulation monitoring for generator rotors, preventing winding damage. Installed in protection/excitation panels.

Product functions(ANSI):50N/51N | 50G/51G

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9884 Generator Differential Protection Relay
details
GWZC-9884 Generator Differential Protection Relay(87G)

Product Overview : The ​GWZC-9884​ is a generator differential relay offering fast fault protection with harmonic restraint, ideal for power plants and industrial generators (6.6kV–24kV).

Product functions(ANSI):87H | 87 | 87A | 49

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZW-9883  Generator Comprehensive Protection Relay
details
GWZW-9883 Generator Comprehensive Protection Relay

 Product Overview:The VIP-96S88C is a generator comprehensive protection relay that integrates differential protection and backup protection.

Product functions(ANSl):87G;60FL;50;50N;51;51N;51AC;40;49;46;46IT;58/59N;60FL;74;81L/81R

Communication functions:Ethernet 103, MODBUS RTU, 2×ETH, 2×RS485

Technical Knowledge More
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Generator Overfrequency Protection
Generator Overfrequency Protection: Working Principle, Function, and Setting Calculation
   In our previous session, we covered the working principle, function, and setting calculation of generator Underfrequency Protection. Today, we will discuss the working principle, function, and setting calculation of generator Underfrequency Protection, as detailed below: Generator Overfrequency Protection, internationally standardized under ANSI/IEEE C37.2 as code 81O, operates on the core principle of continuously monitoring the AC voltage frequency at the generator terminals or the point of interconnection.
2025/10/22
generator reverse power protection
Generator Underfrequency Protection: Working Principle, Function, and Setting Calculation
Generator Underfrequency Protection, internationally standardized under ANSI/IEEE C37.2 as code 81, operates on a core principle of continuously monitoring the AC voltage frequency at the generator terminals or at the station auxiliary bus. Relationship between Frequency and Speed: For a synchronous generator, the output electrical frequency f is directly proportional to the rotor speed N and the number of pole pairs P (f = (P * N) / 120). Therefore, a decrease in system frequency directly indicates a decrease in the prime mover (turbine) speed, signifying that the mechanical input power is less than the electrical output power, putting the generator in a motoring condition.
2025/10/21