Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home

Differential protection relay related product

GWZC-9913 FO Line Diff Relay(87L)
details
GWZC-9913 FO Line Diff Relay(87L)

Product Overview : This FO Line Diff Relay protects 132kV and below transmission lines in ungrounded/low-resistance systems, offering primary/backup protection with monitoring. Supports switchgear/panel mounting via fiber channels with E1 interface.

Product functions(ANSI):87L |50/51 | 51 |50N/51N | 51N | 81U | 49 | 79 | 60 | 60 | 60 | 60/51 | 94 |21

Communication functions : IEC61850 | IEC 60870-5-103 |MODBUS RTU |2× Ethernet Ports | 2× RS-485

GWZC-9916 Bus differential protection relay
details
GWZC-9916 Bus differential protection relay

Product Overview : GWZC-9916 Bus Differential Protection Relay Applicable for voltage levels up to 132kV, supporting various busbar configurations including single bus, sectionalized single bus, triple-section single bus, double bus, double bus with single section, and double bus with double sections.

Product functions(ANSI):87 | 50BF | 50BF | 50 | 60 | 60 | 60 | 50 | 27

Communication functions : IEC61850 |​​IEC 60870-5-103 |MODBUS RTU |3× Ethernet Ports |3× RS-485

GWZC-9884 Generator Differential Protection Relay
details
GWZC-9884 Generator Differential Protection Relay(87H | 87 | 87A)

Product Overview : The ​GWZC-9884​ is a generator differential relay offering fast fault protection with harmonic restraint, ideal for power plants and industrial generators (6.6kV–24kV).

Product functions(ANSI):87H | 87 | 87A | 49

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9826 Main Transformer Differential Protection Relay
details
GWZC-9826 Main Transformer Differential Protection Relay(87H | 87 | 87A)

Product Overview: GWZC-9826​ is a fast-acting (<30ms) ​transformer differential relay​ for ​33kV–110kV systems, featuring harmonic restraint. Used in substations and industrial plants for transformer protection.

Product functions(ANSI):87H | 87 | 87A | 60

Communication functions: IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU |2× Ethernet Ports |2× RS-485

GWZC-9833 Motor Magnetic Balance Differential Protection Relay
details
GWZC-9833 Motor Magnetic Balance Differential Protection Relay (87M)

Product Overview : GWZC-9833​ provides magnetic balance differential protection for HV motors, with overcurrent and thermal protection. Installed in motor control centers, it safeguards critical industrial motors with fault recording capability.

Product functions(ANSI):87M | 50 | 51 | 51 | 51 | 49 | 48 | 50Q | 46 | 46 | 50N/51N | 49 | 48 | 86 | 59 | 27 | 59N | 81O | 81U | 60FL | 27 | 74 | 27/81U | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9821C Transformer Differential Protection Relay
details
GWZC-9821C Transformer Differential Protection Relay (87H | 87 | 87AL)

Product Overview: The ​GWZC-9821C​ is a transformer differential relay that detects internal faults while preventing inrush false trips. Installed in substation panels, it provides reliable protection for power transformers in utility/industrial systems.

Product functions(ANSI):87H | 87 | 87AL | 50/51 | 51V | 49 | 46 | 46 | 50N/51N | 51N | 59 | 27 | 59N | 60FL | 60 | 60CT | 74 | 27D | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

GWZC-9811C Line differential protection relay
details
GWZC-9811C Line differential protection relay (87H | 87)

Product Overview : The GWZC-9811C line differential protection relay is specifically designed for power distribution systems up to 66kV, featuring pilot-wire differential protection technology for fast fault clearance.

Product functions(ANSI):87H | 87 | 87A | 50 | 51 | 51V | 49 | 46 | 50N/50G | 59 | 27 | 81 | 30

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 2× Ethernet Ports | 2× RS-485

Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my