GWZC-9614Bus differential protection relay
GWZC-9614Bus differential protection relay
GWZC-9614 Bus differential protection relay

Applicable Scope :GWZC-9614 Bus Differential Protection Relay supports a maximum of 24 branches for connected components. For neutral ungrounded systems, the capacity extends to 36 branches when protection connects to only two-phase CTs.

Product functions(ANSI):87 | 50BF | 50BF | 50 | 60 | 60 | 60 | 50 | 27

Communication functions : IEC61850 | ​​IEC 60870-5-103 | MODBUS RTU | 3× Ethernet Ports | 3× RS-485

Other functions : Rapid and highly-sensitive dual slope percent differential protection, operating time of entire set below 15ms. 48 Samples/Cycle sampling frequency.

Product Introduction Technical Parameter Size

GWZC-9614 Bus Differential Protection Relay Product Introduction:

        GWZC-9614 Bus Differential Protection Relay Applicable for voltage levels up to 132kV, supporting various busbar configurations including single bus, sectionalized single bus, triple-section single bus, double bus, double bus with single section, and double bus with double sections.

          The GWZC-9614 Bus Differential Protection Relay supports a maximum of 24 branches for connected components. For neutral ungrounded systems, the capacity extends to 36 branches when protection connects to only two-phase CTs.

 

GWZC-9614 Bus Differential Protection Relay Product functions(ANSI)

1.Differential Protection (ANSI 87)
2.Breaker Failure Protection (ANSI 50BF)
3.Bus Coupler/Section Breaker Failure Protection (ANSI 50BF)
4.Bus Coupler/Section Dead Zone Protection (ANSI 50)
5.CT Open Circuit Blocking (High Threshold) (ANSI 60)
6.CT Open Circuit Alarm (Low Threshold) (ANSI 60)
7.PT Open Circuit Alarm (ANSI 60)
8.Bus Coupler/Section Charging Overcurrent Protection (ANSI 50)
9.Voltage Unblocking for Line Breaker Failure (ANSI 27)

Features of GWZC-9614 Bus Differential Protection Relay

1.Fast and highly sensitive Multi-Criteria Ratio Differential Protection with overall operation time below 15ms.
2.Sampling frequency achieves 48 points per cycle.
3.Variable-characteristic differential algorithm based on full-process transient saturation measurement delivers strong resistance to saturation.
4.Complete independence between protection elements and blocking elements ensures reliable blocking circuit.
5.CT ratio settable on-site according to actual transformation ratio.
6.Adaptive bus operation mode automatically corrects errors in disconnector auxiliary contacts.
7.Protection logic visualization and analysis capability.
8.Communication protocols comply with power industry standards: IEC 60870-5-103 or IEC 61850 (optional).
9.Adaptive reception for three GPS time synchronization modes: second-pulse, minute-pulse, and IRIG-B, with autonomous mode discrimination.

Related products More
GWZC-9000 Busbar Protection Panel
GWZC-9000 Busbar Protection Panel
detail
GWZC-9661 Bus Tie Protection Relay
GWZC-9661 Bus Tie Protection & Control Relay
detail
GWZC-9663 Bus-Tie Automatic Transfer Protection Relay
GWZC-9663 Bus-Tie Automatic Transfer Protection Relay
detail
GWZC-9613 FO Line Diff Relay(87L)
GWZC-9613 FO Line Diff Relay(87L)
detail
GWZC-9683 Generator Differential Protection Relay(87G)
GWZC-9683 Generator Differential Protection Relay
detail
Technical Knowledge More
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Transformer Protection Relay Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.
2025/11/24
GWZC-9614Bus differential protection relay
Inquiry Consultation
产品表单
code img
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my