Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home
Home -Air-Insulated Switchgear(AIS)
Outgoing-Feeder-Switchgear
Outgoing-Feeder-Switchgear
15KV-10KV Outgoing Feeder Switchgear

Product Overview: 15KV-10KV Medium Voltage (MV) Outgoing Feeder Switchgear is a critical component in power distribution systems for controlling, protecting, and isolating electrical circuits at voltage levels up to 15KV (including 12KV/11KV/10KV). Designed to comply with IEC 62271 standards, these metal-enclosed switchgear assemblies are widely used in industrial, commercial, and utility networks. Key components include circuit breakers, disconnectors, protection relays, and advanced monitoring systems, offering high safety and modular configurability.

Rated Voltage : 10KV/11KV/12KV/15KV
Rated Current : 630A/1250A/1600A/2000A/2500A
Short-Circuit Breaking Capacity : 20KA/25KA/31.5KA/40KA
IP Rating : IP4X (Enclosure)/IP2X (Front Panel)
Insulation Medium : Air Insulation/SF6 Gas Insulation
Operating Mechanism :  Spring-Charged/Motorized/Manua

Common Chinese ModelsKYN28-12;XGN15-12;HXGN-10;MNS-12

Product Introduction Technical Parameter Size

1. Product Description 
        15KV/11KV/10KV Outgoing Feeder Switchgear serves as the backbone of power distribution systems, featuring either fixed or withdrawable designs. The enclosure is constructed from cold-rolled steel plates with compartmentalization meeting “Five-Prevention Interlock” requirements (e.g., preventing circuit breaker operation under load).
        Main busbars utilize copper conductors with epoxy resin or SMC insulation, ensuring dielectric strength. Typical applications include:
        10-15KV substation outgoing feeders
        Industrial plant power distribution
        Renewable energy grid interconnection
        Data center dual-source transfer
        Certified through type tests (TTA) and internal arc fault tests (IAC AFLR Class), the equipment guarantees reliable operation under extreme conditions.

2. Product Functions
        Power Distribution: Busbar systems enable multi-circuit power routing (single/double bus configurations).
        Protection: Integrated overcurrent, instantaneous trip, and earth fault protection with digital relays.
        Monitoring: Optional sensors for real-time temperature, partial discharge, and mechanical state tracking.
        Isolation: Visible break disconnectors with mechanical interlocks for maintenance safety.
        Communication: IEC 61850 protocol support for SCADA integration.
        Advanced options:
        Arc flash detection system
        Wireless temperature monitoring
        Fault waveform recording

3. Standard & Optional Configurations
Standard:
        Vacuum circuit breaker (VS1/ZN63 series)
        Current transformers (0.2S/5P20 class)
        Voltage transformers (JDZ10 type)
        Surge arresters (HY5WZ ZnO type)
        Voltage presence indicators (DXN-Q type)

Optional:
        Intelligent control unit (with voice prompts)
        Condensation prevention heaters
        SF6 gas density monitors (for gas-insulated units)
        Automatic transfer switches (ATS)

4. Key Features
Safety:
        Passed 40kA/4s short-circuit withstand tests
        Pressure relief flaps for internal arc fault mitigation

Reliability:
        Circuit breaker mechanical endurance ≥10,000 operations
        Main circuit contact resistance ≤50μΩ

Smart Grid Ready:
        Modbus RTU/DNP3.0 protocol support
        RFID-based contact temperature telemetry

Eco-Friendly:
SF6-free alternatives (dry air insulation available)
90% recyclable steel content

15kV-10kV outgoing switchgear Technical Specifications

15kV-10kV outgoing switchgear Technical Specifications

Common Chinese Models & Dimensions

Common Chinese Models Dimensions

Related products More
10-15KV Incoming Line Switchgear
Incoming-Line-Switchgear
detail
11kv Medium-Voltage Switchgear
11kV Switchgear
detail
FZN25-12 series load switchgear
FZN25-12 series load switchgear
detail
KYN61-40.5 withdrawable AC metal-enclosed high-voltage switchgear
detail
XGN17-40.5 fixed-type high-voltage switchgear
XGN17-40.5 fixed-type high-voltage switchgear
detail
technical knowledge More
Gas-Insulated Switchgear (GIS)
Gas-Insulated Switchgear (GIS) for High-Altitude Applications
For Gas-Insulated Switchgear (GIS), since the main live circuits are enclosed within sealed, gas-filled compartments and external connections utilize solid insulation, the insulation performance is unaffected by atmospheric pressure. The primary consideration for GIS at high altitudes is the mechanical strength of the gas enclosure (gas compartment).
2025/08/08
switchgear
What are the differences between IEC-standard switchgear and UL-standard switchgear?
IEC standard switchgear and UL standard switchgear (represented by UL1558 and UL891) fall under different technical systems in power systems, with differences mainly reflected in their standard frameworks, structural design, performance requirements, and applicable scenarios. The following is a comprehensive comparative analysis:
2025/08/08
Ring Main Unit
Technical Requirements and Specifications for 17.5kV Ring Main Units in the Saudi National Grid
SEC Specifications: 17.5kV Ring Main Unit (RMU) - Key Features         Outdoor Enclosure: Designed for outdoor installation.         Dedicated Cable Withstand Voltage Test Terminal Compartment: Features a separate, accessible compartment for cable high-potential (Hi-Pot) testing.         Self-Powered Protection Unit: Utilizes an internal power source for the protection relay.         SF6 Insulated, Single-Tank Design F+F+V Configuration: Common SF6 gas tank housing a combination of Load Switch (F) + Load Switch (F) + Circuit Breaker (V).         Ratings: Ring Switch Unit: 630A. Feeder Circuit Breaker: 200A.         Compliance Standard: SEC Standard 32-SDMS-11.
2025/08/08
Outgoing-Feeder-Switchgear
Inquiry Consultation
产品表单
Inquiry Consultation
+86-13655813785
+86-13655813785
+86-13655813785
+86-13655813785
home product email
live chat
my