10-15KV Incoming Line Switchgear

Product Introduction:This product is a key device in 15/12/11/10 kV power systems, used for receiving and distributing high-voltage electricity. It acts as the main distribution unit in substations or grids, supplying power from the upstream network or generator to local distribution systems. It also offers protection, monitoring, and control to ensure safe and stable operation. Compliant with international standards (e.g., IEC, ANSI), it is widely applied in industrial, commercial, infrastructure, and public utility power systems.

Rated Voltage: 15kV ,12KV,11KV,10KV
Rated Current: 630A–4000A (configurable per load requirements)
Short-Circuit Breaking Capacity: 25kA–50kA (IEC standard)
Insulation Level: 28kV power frequency withstand/75kV lightning impulse
Ingress Protection: IP4X (enclosure)/IP2X (internal compartments)
Operating Mechanism: Spring-charged/motorized/manual

common models:XGN15-12,KYN28-12

Product Introduction Technical Parameter Size

1. Product Description
      The 11kV Incoming Feeder Panel is a modular, metal-enclosed switchgear assembly integrating vacuum circuit breakers (VCB), disconnectors, current/voltage transformers, protective relays, and intelligent monitoring systems. Its compartmentalized design segregates breaker, busbar, cable, and control zones per IEC arc-flash safety standards (IAC AFLR certified). Core capabilities include power intake, short-circuit interruption, overload protection, and earth fault detection, with SCADA connectivity via IEC 61850 protocol. Typical deployments span oil & gas facilities, data centers, mining operations, and urban grid networks, with operational tolerance from -25°C to +55°C.

2. Product Functions
      Power Distribution: Securely routes 15KV-12KV-11kV-10KV supply to downstream transformers or busbars.
      Protection Schemes: Microprocessor-based relays for overcurrent, instantaneous trip, earth leakage, and undervoltage protection.
      Safety Interlocks: Mechanical blocking mechanisms prevent live switching operations.
      Condition Monitoring: Real-time measurement of current, voltage, and power quality parameters with Modbus/DNP3/IEC 61850 communication.
      Event Recording: Fault waveforms and sequence-of-events (SOE) logging for diagnostics.
      Modularity: Optional metering, capacitor bank, or grid synchronization modules.

3. Product Configuration
      Circuit Breaker: Vacuum or SF6 type with spring-operated/motorized mechanism.
      Instrument Transformers: Epoxy-resin encapsulated CT/PT (0.2/0.5 class accuracy).
      Protection Relay: Numerical relays (e.g., Siemens 7SJ82, ABB REF615).
      Enclosure: Galvanized steel/stainless steel with corrosion-resistant coating.
      Ancillaries: Space heaters, LED lighting, hygrothermal controllers.
      Options: HMI touchscreen, wireless temperature sensors, surge arresters.

4. Product Features
      High Availability: Vacuum interruption technology, 10,000 mechanical operations lifespan.
      Smart Grid Ready: Remote condition monitoring and predictive maintenance capabilities.
      Space Optimization: Compact footprint for constrained installations.
      Eco-Design: SF6-free alternatives (VCB) meeting RoHS directives.
      Customization: Tailored dimensions, RAL color codes, and functional modules.
      Interoperability: Multi-vendor protection device integration support.

1. Rated Parameters
      Rated Voltage: 15kV,12kV, 11kV, 10kV
      Maximum Operating Voltage: 12kV
      Rated Current: 630A, 1250A, 1600A, 2000A, 2500A, etc. (varies by model)
      Rated Frequency: 50Hz/60HZ

2. Insulation & Withstand Voltage
      Power Frequency Withstand Voltage (1min): 42kV
      Lightning Impulse Withstand Voltage (Peak): 75kV

3. Short-Circuit Withstand Capability
      Rated Short-Time Withstand Current (4s): 16kA, 20kA, 25kA, 31.5kA, 40kA, 50kA, etc.
      Rated Peak Withstand Current: 40kA, 50kA, 63kA, 100kA, 125kA

4. Structural Features
      Protection Level: IP4X (standard)
      Enclosure Type: Metal-clad withdrawable (e.g., KYN28-12), fixed type (e.g., XGN2)
      Busbar Rated Current: 630A ~ 3150A

5. Environmental Adaptability
      Altitude: ≤2000m (requires high-altitude adaptation beyond this)
      Ambient Temperature: -20℃ ~ +40℃ (heating required below -5℃)
      Relative Humidity: ≤90% (at 25℃)

6. Other Key Features
      Five-Protection Function: Prevents misoperation of circuit breakers, access to live compartments, etc.
      Circuit Breaker Type: Vacuum circuit breaker (compliant with IEC 56 standard)
      Mechanical Life: 20,000 operations (for circuit breakers)
      For more detailed specifications (e.g., KYN28-12, XGN2) or custom parameters, please refer to the manufacturer’s technical documentation.

Related products More
11kv Medium-Voltage Switchgear
11kV Switchgear
detail
Ring Main Unit (RMU)
Ring Main Unit (RMU)
detail
KYN28-12 Metal-Clad Withdrawable Medium Voltage Switchgear
KYN28-12 Metal-Clad Withdrawable Medium Voltage Switchgear
detail
FZN25-12 series load switchgear
FZN25-12 series load switchgear
detail
KYN61-40.5 withdrawable AC metal-enclosed high-voltage switchgear
detail
technical knowledge More
Gas-Insulated Switchgear (GIS)
Gas-Insulated Switchgear (GIS) for High-Altitude Applications
For Gas-Insulated Switchgear (GIS), since the main live circuits are enclosed within sealed, gas-filled compartments and external connections utilize solid insulation, the insulation performance is unaffected by atmospheric pressure. The primary consideration for GIS at high altitudes is the mechanical strength of the gas enclosure (gas compartment).
2025/08/08
switchgear
What are the differences between IEC-standard switchgear and UL-standard switchgear?
IEC standard switchgear and UL standard switchgear (represented by UL1558 and UL891) fall under different technical systems in power systems, with differences mainly reflected in their standard frameworks, structural design, performance requirements, and applicable scenarios. The following is a comprehensive comparative analysis:
2025/08/08
Ring Main Unit
Technical Requirements and Specifications for 17.5kV Ring Main Units in the Saudi National Grid
SEC Specifications: 17.5kV Ring Main Unit (RMU) - Key Features         Outdoor Enclosure: Designed for outdoor installation.         Dedicated Cable Withstand Voltage Test Terminal Compartment: Features a separate, accessible compartment for cable high-potential (Hi-Pot) testing.         Self-Powered Protection Unit: Utilizes an internal power source for the protection relay.         SF6 Insulated, Single-Tank Design F+F+V Configuration: Common SF6 gas tank housing a combination of Load Switch (F) + Load Switch (F) + Circuit Breaker (V).         Ratings: Ring Switch Unit: 630A. Feeder Circuit Breaker: 200A.         Compliance Standard: SEC Standard 32-SDMS-11.
2025/08/08
Incoming-Line-Switchgear
Inquiry Consultation
产品表单
Inquiry Consultation
+86-13655813785
+86-13655813785
+86-13655813785
+86-13655813785
home product email
live chat
my