GWZC-9833 Motor Magnetic Balance Differential Protection Relay
Motor Magnetic Balance Differential Protection Relay Side View
Motor Magnetic Balance Differential Protection Relay Rear View
GWZC-9833 Motor Magnetic Balance Differential Protection Relay
Motor Magnetic Balance Differential Protection Relay Side View
Motor Magnetic Balance Differential Protection Relay Rear View
GWZC-9833 Motor Magnetic Balance Differential Protection Relay (87M)

Applicable Scope:The ​GWZC-9833​ is a motor protection relay featuring ​magnetic balance differential protection​ for detecting internal winding faults, along with overcurrent and thermal protection. Installed in ​motor control centers and HV switchgear, it safeguards ​industrial motors​ in power plants and large facilities, with built-in fault recording for diagnostics.

Product functions(ANSI):87M | 50 | 51 | 51 | 51 | 49 | 48 | 50Q | 46 | 46 | 50N/51N | 49 | 48 | 86 | 59 | 27 | 59N | 81O | 81U | 60FL | 27 | 74 | 27/81U | 30

Communication functions:
Supported Protocols:​​IEC 60870-5-103 (over Ethernet) | MODBUS RTU (via RS-485) | IEC 61850 (Ed.2 or Ed.1, as applicable)
​Interfaces:​​2× Ethernet Ports​ (IEEE 802.3 compliant, 10/100 Mbps) | 2× RS-485 Ports​ (ANSI/TIA-485-A standard, galvanically isolated)

Other functions: Support time synchronization via communication message, SNTP (Simple Network Time Protocol) time synchronization, and IRIG-B time synchronization. Support the dot matrix printing function with serial port communication. Support the fault recording function

Product Introduction Technical Parameter Size

Product Introduction:

          The ​GWZC-9833 Motor Magnetic Balance Differential Protection Relay​ is designed for ​high-voltage motor protection, providing ​magnetic balance differential protection​ to detect internal winding faults, along with ​overcurrent, phase unbalance, and thermal overload protection.

          Motor Magnetic Balance Differential Protection Relay​ is typically installed in ​motor control centers (MCCs), high-voltage switchgear panels, and motor protection cubicles​ within ​industrial plants, power stations, and large pumping systems, ensuring rapid fault isolation and minimizing motor damage. The relay also features ​fault recording and event logging​ for enhanced diagnostics and maintenance.

Product functionsANSI):

1.Magnetic Balance Differential Protection (ANSI 87M)
2.Instantaneous Overcurrent Protection (ANSI 50)
3.Time-Delayed Overcurrent Protection (ANSI 51)
4.Time-Delayed Overcurrent Protection (ANSI 51)
5.Inverse Time Overcurrent Protection (ANSI 51)
6.Overload Protection (ANSI 49)
7.Stall Protection (ANSI 48)
8.Negative Sequence Instantaneous Overcurrent Protection (ANSI 50Q)
9.Negative Sequence Time-Delayed Overcurrent Protection (ANSI 46)
10.Negative Sequence Inverse Time Overcurrent Protection (ANSI 46)
11.Residual Overcurrent Protection (ANSI 50N/51N)
12.Thermal Overload Protection (ANSI 49)
13.Long Starting Time Protection (ANSI 48)
14.Motor Starting Block (ANSI 86)
15.Overvoltage Protection (ANSI 59)
16.Undervoltage Protection (ANSI 27)
17.Residual Overvoltage Protection (ANSI 59N)
18.Overfrequency Protection (ANSI 81O)
19.Underfrequency Protection (ANSI 81U)
20.Potential Transformer Fuse Failure (ANSI 60FL)
21.Potential Transformer Loss of Voltage (ANSI 27)
22.Control Circuit Supervision (ANSI 74)
23.Loss of Mains Protection (ANSI 27/81U)
24.Non-Electrical Protection (ANSI 30)

Electrical Specifications​

​Power Supply:​​

● AC: 85-264V, 47-63Hz (≤15% THD)
● DC: 100-370V (≤5% ripple)

​Rated AC Parameters:​​

● Voltage: 100V/√3 or 100V
● Current: 5A/1A
● Frequency: 50Hz

​Overload Capacity:​​

● Current Circuit: 2×In continuous | 10×In (10s) | 40×In (1s)
● Voltage Circuit: 1.5×Un continuous

​Power Consumption:​​

● Supply: <10W (static), ≤15W (trip)
● Current Circuit: ≤1VA/phase (5A) / ≤0.5VA/phase (1A)
● Voltage Circuit: ≤0.5VA/phase

​Digital Output:​​

● Dry contact (8A@250VAC / 30VDC)
● Dielectric: 4kVAC (coil-contact), 1kVAC (open contact)
● Operating Time: 5ms (typ) / 8ms (max)
● Mechanical Life: 100k operations

​Protection Performance​

​Operating Range:​​

● Voltage: 0.5-120V (phase)
● Current: 0.02-20×In
● Zero-Seq Current: 0.05-20A
● Frequency: 35-65Hz | Delay: 0-100s

​Accuracy:​​

● Voltage/Current: ±2.5% or ±0.1V/±0.05A (whichever greater)
● Frequency: ±0.01Hz
● Settings: ±2.5%

​Trip Time:​​

● Instantaneous: ≤35ms (≥1.2× setting)
● Time-Delayed: ≤1% of setting or 35ms

​Measurement & Monitoring​

​Range:​​

● Voltage: 0.5-120V | Current: 0.02-1.2×In

​Accuracy:​​

● V/I: ±0.2% | Frequency: ±0.01Hz | Other: 0.5%
● Time Sync: ≤2ms | SOE: ≤1ms

​Event Recording:​​

● 128 protection trips/operations
● 32 self-tests/fault waveforms (COMTRADE)

​Environmental & Mechanical​

​Operating Temp:​​

● Standard: -10°C to +55°C
● Extended: -40°C to +70°C

​Storage Temp:​​ -40°C to +80°C
​Humidity:​​ 5-90% RH (non-condensing)
​Pressure:​​ 60-110 kPa
​Compliance:​​

● IEC 60255-21 (vibration/shock)
● IEC 61000-6 (EMC)

Related products More
GWZC-9913 FO Line Diff Relay(87L)
GWZC-9913 FO Line Diff Relay(87L)
detail
GWZC-9916 Bus differential protection relay
GWZC-9916 Bus differential protection relay
detail
GWZC-9884 Generator Differential Protection Relay(87H | 87 | 87A)
GWZC-9884 Generator Differential Protection Relay
detail
GWZC-9826 Main Transformer Differential Protection Relay(87H | 87 | 87A)
GWZC-9826 Main Transformer Differential Protection Relay
detail
GWZC-9821C Transformer Differential Protection Relay (87H | 87 | 87AL)
GWZC-9821C Transformer Differential Protection Relay
detail
Technical Knowledge More
Wireless Temperature Monitoring System for Substations
Wireless Temperature Monitoring System: Application in Switchgear​
This article introduces the application of wireless temperature monitoring systems in high-voltage and low-voltage switchgear. The configuration of the wireless temperature monitoring system varies across different equipment. If you need a customized wireless temperature monitoring solution for your project, please visit our website for more information.
2025/09/08
GWZC-9804 Arc Flash Protection Relay
Switchgear Arc Flash Protection System Configuration Scheme
This article introduces the configuration scheme for a switchgear arc flash protection system. Busbar arc flash protection monitors the busbar compartment and trips the incoming breaker, while feeder arc flash protection monitors the circuit breaker compartment and cable compartment to trip the feeder breaker. A proper arc flash protection system configuration scheme can effectively protect personnel and equipment safety. For information on a reliable arc flash protection system configuration scheme, please visit our website.
2025/09/04
Arc Flash Protection Relay
Arc Protection Working Principle and Decision Process
Arc Flash Protection is a specialized safety system engineered to rapidly detect and mitigate destructive electrical arc flash faults. Unlike conventional overcurrent protection, it utilizes a combination of light and current sensors to identify an arc flash event within milliseconds. By triggering a circuit breaker to isolate the fault incredibly fast, Arc Flash Protection significantly reduces the explosive energy released, safeguarding personnel from severe injury and preventing extensive damage to electrical equipment like switchgear. This makes it an indispensable defense layer in industrial, commercial, and utility power systems.
2025/09/03
GWZC-9833 Motor Magnetic Balance Differential Protection Relay
Motor Magnetic Balance Differential Protection Relay Side View
Motor Magnetic Balance Differential Protection Relay Rear View
Inquiry Consultation
产品表单
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my