GWZC-9833 Motor Magnetic Balance Differential Protection Relay
Motor Magnetic Balance Differential Protection Relay Side View
Motor Magnetic Balance Differential Protection Relay Rear View
GWZC-9833 Motor Magnetic Balance Differential Protection Relay
Motor Magnetic Balance Differential Protection Relay Side View
Motor Magnetic Balance Differential Protection Relay Rear View
GWZC-9833 Motor Magnetic Balance Differential Protection Relay (87M)

Applicable Scope:The ​GWZC-9833​ is a motor protection relay featuring ​magnetic balance differential protection​ for detecting internal winding faults, along with overcurrent and thermal protection. Installed in ​motor control centers and HV switchgear, it safeguards ​industrial motors​ in power plants and large facilities, with built-in fault recording for diagnostics.

Product functions(ANSI):87M | 50 | 51 | 51 | 51 | 49 | 48 | 50Q | 46 | 46 | 50N/51N | 49 | 48 | 86 | 59 | 27 | 59N | 81O | 81U | 60FL | 27 | 74 | 27/81U | 30

Communication functions:
Supported Protocols:​​IEC 60870-5-103 (over Ethernet) | MODBUS RTU (via RS-485) | IEC 61850 (Ed.2 or Ed.1, as applicable)
​Interfaces:​​2× Ethernet Ports​ (IEEE 802.3 compliant, 10/100 Mbps) | 2× RS-485 Ports​ (ANSI/TIA-485-A standard, galvanically isolated)

Other functions: Support time synchronization via communication message, SNTP (Simple Network Time Protocol) time synchronization, and IRIG-B time synchronization. Support the dot matrix printing function with serial port communication. Support the fault recording function

Product Introduction Technical Parameter Size

Product Introduction:

          The ​GWZC-9833 Motor Magnetic Balance Differential Protection Relay​ is designed for ​high-voltage motor protection, providing ​magnetic balance differential protection​ to detect internal winding faults, along with ​overcurrent, phase unbalance, and thermal overload protection.

          Motor Magnetic Balance Differential Protection Relay​ is typically installed in ​motor control centers (MCCs), high-voltage switchgear panels, and motor protection cubicles​ within ​industrial plants, power stations, and large pumping systems, ensuring rapid fault isolation and minimizing motor damage. The relay also features ​fault recording and event logging​ for enhanced diagnostics and maintenance.

Product functionsANSI):

1.Magnetic Balance Differential Protection (ANSI 87M)
2.Instantaneous Overcurrent Protection (ANSI 50)
3.Time-Delayed Overcurrent Protection (ANSI 51)
4.Time-Delayed Overcurrent Protection (ANSI 51)
5.Inverse Time Overcurrent Protection (ANSI 51)
6.Overload Protection (ANSI 49)
7.Stall Protection (ANSI 48)
8.Negative Sequence Instantaneous Overcurrent Protection (ANSI 50Q)
9.Negative Sequence Time-Delayed Overcurrent Protection (ANSI 46)
10.Negative Sequence Inverse Time Overcurrent Protection (ANSI 46)
11.Residual Overcurrent Protection (ANSI 50N/51N)
12.Thermal Overload Protection (ANSI 49)
13.Long Starting Time Protection (ANSI 48)
14.Motor Starting Block (ANSI 86)
15.Overvoltage Protection (ANSI 59)
16.Undervoltage Protection (ANSI 27)
17.Residual Overvoltage Protection (ANSI 59N)
18.Overfrequency Protection (ANSI 81O)
19.Underfrequency Protection (ANSI 81U)
20.Potential Transformer Fuse Failure (ANSI 60FL)
21.Potential Transformer Loss of Voltage (ANSI 27)
22.Control Circuit Supervision (ANSI 74)
23.Loss of Mains Protection (ANSI 27/81U)
24.Non-Electrical Protection (ANSI 30)

Electrical Specifications​

​Power Supply:​​

● AC: 85-264V, 47-63Hz (≤15% THD)
● DC: 100-370V (≤5% ripple)

​Rated AC Parameters:​​

● Voltage: 100V/√3 or 100V
● Current: 5A/1A
● Frequency: 50Hz

​Overload Capacity:​​

● Current Circuit: 2×In continuous | 10×In (10s) | 40×In (1s)
● Voltage Circuit: 1.5×Un continuous

​Power Consumption:​​

● Supply: <10W (static), ≤15W (trip)
● Current Circuit: ≤1VA/phase (5A) / ≤0.5VA/phase (1A)
● Voltage Circuit: ≤0.5VA/phase

​Digital Output:​​

● Dry contact (8A@250VAC / 30VDC)
● Dielectric: 4kVAC (coil-contact), 1kVAC (open contact)
● Operating Time: 5ms (typ) / 8ms (max)
● Mechanical Life: 100k operations

​Protection Performance​

​Operating Range:​​

● Voltage: 0.5-120V (phase)
● Current: 0.02-20×In
● Zero-Seq Current: 0.05-20A
● Frequency: 35-65Hz | Delay: 0-100s

​Accuracy:​​

● Voltage/Current: ±2.5% or ±0.1V/±0.05A (whichever greater)
● Frequency: ±0.01Hz
● Settings: ±2.5%

​Trip Time:​​

● Instantaneous: ≤35ms (≥1.2× setting)
● Time-Delayed: ≤1% of setting or 35ms

​Measurement & Monitoring​

​Range:​​

● Voltage: 0.5-120V | Current: 0.02-1.2×In

​Accuracy:​​

● V/I: ±0.2% | Frequency: ±0.01Hz | Other: 0.5%
● Time Sync: ≤2ms | SOE: ≤1ms

​Event Recording:​​

● 128 protection trips/operations
● 32 self-tests/fault waveforms (COMTRADE)

​Environmental & Mechanical​

​Operating Temp:​​

● Standard: -10°C to +55°C
● Extended: -40°C to +70°C

​Storage Temp:​​ -40°C to +80°C
​Humidity:​​ 5-90% RH (non-condensing)
​Pressure:​​ 60-110 kPa
​Compliance:​​

● IEC 60255-21 (vibration/shock)
● IEC 61000-6 (EMC)

Related products More
GWZC-9913 FO Line Diff Relay(87L)
GWZC-9913 FO Line Diff Relay(87L)
detail
GWZC-9916 Bus differential protection relay
GWZC-9916 Bus differential protection relay
detail
GWZC-9884 Generator Differential Protection Relay(87H | 87 | 87A)
GWZC-9884 Generator Differential Protection Relay
detail
GWZC-9826 Main Transformer Differential Protection Relay(87H | 87 | 87A)
GWZC-9826 Main Transformer Differential Protection Relay
detail
GWZC-9821C Transformer Differential Protection Relay (87H | 87 | 87AL)
GWZC-9821C Transformer Differential Protection Relay
detail
Technical Knowledge More
Automatic Transfer Switch (ATS) Side View
What is Parallel Operation
​Parallel operation​ involves connecting two or more independent AC power sources (e.g., generators, grids) to share electrical loads seamlessly. This process—synchronization—demands precise matching of voltage magnitude, frequency, and phase angles between systems before interconnection. Critical for grid expansion, backup power, and renewable integration, it enables redundant supply during failures.
2025/08/15
Generator-Transformer Differential Protection Relay Rear View
Ring-Closing Operation: Definition & Importance in Power Grids
A ring-closing operation involves closing a normally open switch within a closed-loop electrical network fed by a single power source. This creates parallel paths to redistribute loads without interruption, primarily for maintenance or network reconfiguration. Key prerequisites are voltage difference under 5%, phase angle alignment below 5 degrees, and pre-calculation of induced circulating currents to avoid equipment damage. Distinct from connecting independent systems, this procedure requires advanced monitoring but avoids synchronization complexity. Strict protocols using real-time sensors and simulations ensure safe execution, making it fundamental for resilient distribution networks like ring-main units (RMUs) in urban grids.
2025/08/14
Synchronism Check Function vs. Synchronizing Function: Roles, Differences, and Applications
This article compares the ​synchronism check function​ in line protection devices and the ​synchronizing function​ in dedicated synchronizing equipment. The ​synchronism check function​ serves as a safety interlock for circuit breaker closing operations, while the ​synchronizing function​ enables precise generator synchronization and critical tie-line interconnections with active parameter regulation. Explore core principles, application scenarios, and technical distinctions between these critical power system components.
2025/08/11
GWZC-9833 Motor Magnetic Balance Differential Protection Relay