GWZC-9586 Low-voltage generator protection relay

Scope of Application: The GWZC-9586 low-voltage generator protection relay is suitable for backup protection of 400V low-voltage generators below 1000kW. It can be installed in panels or locally in switchgear.

Protection Functions(ANSI): 50 | 51 | 50N | 51N | 50I | 50V | 32 | 81U | 80O | 59 | 27

Monitoring and Control Functions: • 14 channels of remote signal input collection; • 8 channels of relay outputs; • Event SOE recording

Communication Functions: 2 Ethernet interfaces (supporting Ethernet 103 protocol, optional); 1 RS485 communication port (supporting Modbus-RTU protocol)

Product Introduction Technical Parameter Size

Product Introduction
       The GWZC-9586 low-voltage generator protection relay is primarily designed for the protection of 400V low-voltage generators below 1000kW, serving as a comprehensive and practical backup protection solution. With its compact and aesthetically pleasing design, along with reliable quality, this generator protection relay is the most ideal choice for low-voltage generator sets.

Protection Functions(ANSI)
       Phase Time Overcurrent Protection (ANSI 50/51)
       Inverse Time Overcurrent Protection (ANSI 51)
       Overload Protection (ANSI 49)
       Zero-Sequence / Ground Overcurrent Protection (ANSI 50N/51N)
       Overvoltage Protection (ANSI 59)
       Undervoltage Protection (ANSI 27)
       Overfrequency Protection (ANSI 81O)
       Underfrequency Protection (ANSI 81U)
       Reverse Power Protection (ANSI 32)
       CT Circuit Failure Protection (ANSI 74C)
       PT Circuit Failure Protection (ANSI 74V)
       Control Circuit Failure Protection (ANSI 74)
       System Supply Loss Protection (ANSI 27)
       Non-Electrical Protection (ANSI 30)

Monitoring and Control Functions
       Voltage: Ua, Ub, Uc, Uab, Ubc, Uca
       Current: Ia, Ib, Ic, Ia, Ib, Ic, 3I0
       Power Parameters: P (Active Power), Q (Reactive Power), S (Apparent Power), Cosφ (Power Factor)

Frequency: f
       Electrical Energy:
       EP+ (Active Energy Import)
       EP- (Active Energy Export)
       EQ+ (Reactive Energy Import)
       EQ- (Reactive Energy Export)

       14-channel Binary Input (Status Input) Acquisition
       8-channel Relay Output
       Event Sequence of Events (SOE) Recording

Communication Function

Communication Interfaces:
       2 Ethernet ports (Supporting IEC 60870-5-103 protocol, configurable option).
       1 RS485 communication port (Supporting Modbus-RTU protocol).

Time Synchronization Function:
       Supports time synchronization via communication messages, SNTP, and IRIG-B code.

Related products More
GWZC-9000 Generator protection panel​
Generator Protection Panel
detail
GWZC-9884 Generator Differential Protection Relay(87G)
GWZC-9884 Generator Differential Protection Relay
detail
GWZC-9885 Generator Rotor Earth Fault Protection Relay
GWZC-9885 Generator Rotor Earth Fault Protection Relay
detail
GWZW-9883 Generator Comprehensive Protection Relay
GWZW-9883  Generator Comprehensive Protection Relay
detail
GWZC-9887 Generator-Transformer Differential Protection Relay (87G|87T)
GWZC-9887 Generator-Transformer Differential Protection Relay
detail
Technical Knowledge More
Motor protection relay
Function and Protection Scope of Generator Differential Protection
Generator differential protection is one of the most critical primary protections in generator relaying systems. Its core function is to rapidly and reliably clear internal short-circuit faults in generators, preventing severe equipment damag
2025/06/25
Other Relays
Generator Differential Protection: Working Principle & Key Features
In this article, we explore the ​working principle of generator differential protection, its key components, and why it is critical for power system reliability.
2025/06/20
GWZC-9886-Generator-Backup-Protection-Relay
Generator Reverse Power Protection: Working Principle, Function, and Setting Calculation
Reverse Power Protection is fundamentally a directional power protection used to detect the flow of active power.         Core Principle: It calculates the active power internally within the relay based on the measured voltage and current at the generator terminals (or outlet). The active power is calculated using the formula P = √3 × V × I × cosφ, where cosφ is the power factor.
2025/10/20
marine generator protection relay
What relay protection functions should be configured for a marine generator?
Generator protection devices must include at least the following core protection functions. Additional functions may be required depending on system configuration (e.g., generator capacity, parallel operation, neutral grounding method): 1.Overcurrent Protection (50/51):           Instantaneous Overcurrent (50): Clears severe phase-to-phase short-circuit faults with extremely fast operation (millisecond level).           Definite Time / Inverse Time Overcurrent (51): Clears remote or moderate overloads and short-circuit faults, providing backup protection. Must coordinate with downstream protection (e.g., feeder breakers) to ensure selectivity. Inverse time characteristics better match equipment thermal withstand capability.           Short-Circuit Backup Protection: Typically provided by overcurrent protection (51), acting as backup to primary protection (e.g., differential).
2025/08/04
Inquiry Consultation
产品表单
code img
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my