GWZC-9885 Generator Rotor Earth Fault Protection Relay
Generator Rotor Earth Fault Protection Relay Side View
Generator Rotor Earth Fault Protection Relay Rear View
GWZC-9885 Generator Rotor Earth Fault Protection Relay
Generator Rotor Earth Fault Protection Relay Side View
Generator Rotor Earth Fault Protection Relay Rear View
GWZC-9885 Generator Rotor Earth Fault Protection Relay

Applicable Scope :The ​GWZC-9885 Generator Rotor Earth Fault Relay​ provides two-stage protection (alarm/trip) for rotor winding ground faults, monitors insulation resistance, and features self-diagnostics. Installed in generator protection or excitation panels, it safeguards power plant and industrial generators against rotor damage.

Product functions(ANSI):50N/51N | 50G/51G

Communication functions :Supported Protocols :​​ IEC 60870-5-103 (over Ethernet) | MODBUS RTU (via RS-485) | IEC 61850 (Ed.2 or Ed.1, as applicable)
​Interfaces:​​2× Ethernet Ports​ (IEEE 802.3 compliant, 10/100 Mbps) | 2× RS-485 Ports​ (ANSI/TIA-485-A standard, galvanically isolated)

Other functions : Support time synchronization via communication message, SNTP (Simple Network Time Protocol) time synchronization, and IRIG-B time synchronization. Support the dot matrix printing function with serial port communication. Support the fault recording function

Product Introduction Technical Parameter Size

Product Introduction :
          The ​GWZC-9885 Generator Rotor Earth Fault Protection Relay​ is designed to detect and protect against ground faults in generator rotor windings, offering two-stage protection with alarm and trip functions for both low and high-resistance faults.

          GWZC-9885 Generator Rotor Earth Fault Protection Relay continuously monitors insulation resistance to detect early insulation degradation and includes self-testing for reliability.

          GWZC-9885 Generator Rotor Earth Fault Protection Relay​ Typically installed in generator protection panels, excitation control cabinets, or substation relay panels, this relay is essential for synchronous generators in power plants and industrial applications, ensuring safe operation and preventing rotor damage.

Product functionsANSI):

1.Single-Phase Ground Fault Protection (ANSI 50N/51N)
2.Double-Phase Ground Fault Protection (ANSI 50G/51G)

Electrical Specifications​

​Power Supply:​​

● AC: 85-264V, 47-63Hz (≤15% THD)
● DC: 100-370V (≤5% ripple)

​Rated AC Parameters:​​

● Voltage: 100V/√3 or 100V
● Current: 5A/1A
● Frequency: 50Hz

​Overload Capacity:​​

● Current Circuit: 2×In continuous | 10×In (10s) | 40×In (1s)
● Voltage Circuit: 1.5×Un continuous

​Power Consumption:​​

● Supply: <10W (static), ≤15W (trip)
● Current Circuit: ≤1VA/phase (5A) / ≤0.5VA/phase (1A)
● Voltage Circuit: ≤0.5VA/phase

​Digital Output:​​

● Dry contact (8A@250VAC / 30VDC)
● Dielectric: 4kVAC (coil-contact), 1kVAC (open contact)
● Operating Time: 5ms (typ) / 8ms (max)
● Mechanical Life: 100k operations

​Protection Performance

​Operating Range:​​

● Voltage: 0.5-120V (phase)
● Current: 0.02-20×In
● Zero-Seq Current: 0.05-20A
● Frequency: 35-65Hz | Delay: 0-100s

​Accuracy:​​

● Voltage/Current: ±2.5% or ±0.1V/±0.05A (whichever greater)
● Frequency: ±0.01Hz
● Settings: ±2.5%

​Trip Time:​​

● Instantaneous: ≤35ms (≥1.2× setting)
● Time-Delayed: ≤1% of setting or 35ms

Measurement & Monitoring​

​Range:​​

● Voltage: 0.5-120V | Current: 0.02-1.2×In

​Accuracy:​​

● V/I: ±0.2% | Frequency: ±0.01Hz | Other: 0.5%
● Time Sync: ≤2ms | SOE: ≤1ms

​Event Recording:​​

● 128 protection trips/operations
● 32 self-tests/fault waveforms (COMTRADE)

​Environmental & Mechanical​

​Operating Temp:​​

● Standard: -10°C to +55°C
● Extended: -40°C to +70°C*

​Storage Temp:​​ -40°C to +80°C
​Humidity:​​ 5-90% RH (non-condensing)
​Pressure:​​ 60-110 kPa
​Compliance:​​

● IEC 60255-21 (vibration/shock)
● IEC 61000-6 (EMC)

Related products More
GWZC-9887 Generator-Transformer Differential Protection Relay (87G|87T)
GWZC-9887 Generator-Transformer Differential Protection Relay
detail
GWZC-9886 Generator Backup Protection Relay
GWZC-9886 Generator Backup Protection Relay
detail
GWZC-9884 Generator Differential Protection Relay(87H | 87 | 87A)
GWZC-9884 Generator Differential Protection Relay
detail
GWZW-9883 Generator Comprehensive Protection Relay
GWZW-9883  Generator Comprehensive Protection Relay
detail
GOWE-9000 Partial discharge online monitoring system
Partial discharge online monitoring system
detail
Technical Knowledge More
Wireless Temperature Monitoring System for Substations
Wireless Temperature Monitoring System: Application in Switchgear​
This article introduces the application of wireless temperature monitoring systems in high-voltage and low-voltage switchgear. The configuration of the wireless temperature monitoring system varies across different equipment. If you need a customized wireless temperature monitoring solution for your project, please visit our website for more information.
2025/09/08
GWZC-9804 Arc Flash Protection Relay
Switchgear Arc Flash Protection System Configuration Scheme
This article introduces the configuration scheme for a switchgear arc flash protection system. Busbar arc flash protection monitors the busbar compartment and trips the incoming breaker, while feeder arc flash protection monitors the circuit breaker compartment and cable compartment to trip the feeder breaker. A proper arc flash protection system configuration scheme can effectively protect personnel and equipment safety. For information on a reliable arc flash protection system configuration scheme, please visit our website.
2025/09/04
Arc Flash Protection Relay
Arc Protection Working Principle and Decision Process
Arc Flash Protection is a specialized safety system engineered to rapidly detect and mitigate destructive electrical arc flash faults. Unlike conventional overcurrent protection, it utilizes a combination of light and current sensors to identify an arc flash event within milliseconds. By triggering a circuit breaker to isolate the fault incredibly fast, Arc Flash Protection significantly reduces the explosive energy released, safeguarding personnel from severe injury and preventing extensive damage to electrical equipment like switchgear. This makes it an indispensable defense layer in industrial, commercial, and utility power systems.
2025/09/03
GWZC-9885 Generator Rotor Earth Fault Protection Relay
Generator Rotor Earth Fault Protection Relay Side View
Generator Rotor Earth Fault Protection Relay Rear View
Inquiry Consultation
产品表单
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my