GWZC-9682 Generator Rotor Earth Fault Protection Relay
Generator Rotor Earth Fault Protection Relay Side View
Generator Rotor Earth Fault Protection Relay Rear View
GWZC-9682 Generator Rotor Earth Fault Protection Relay
Generator Rotor Earth Fault Protection Relay Side View
Generator Rotor Earth Fault Protection Relay Rear View
GWZC-9682 Generator Rotor Earth Fault Protection Relay

Applicable Scope :The ​GWZC-9682 Generator Rotor Earth Fault Relay​ provides two-stage protection (alarm/trip) for rotor winding ground faults, monitors insulation resistance, and features self-diagnostics. Installed in generator protection or excitation panels, it safeguards power plant and industrial generators against rotor damage.

Product functions(ANSI):50N/51N | 50G/51G

Communication functions :Supported Protocols :​​ IEC 60870-5-103 (over Ethernet) | MODBUS RTU (via RS-485) | IEC 61850 (Ed.2 or Ed.1, as applicable)
​Interfaces:​​2× Ethernet Ports​ (IEEE 802.3 compliant, 10/100 Mbps) | 2× RS-485 Ports​ (ANSI/TIA-485-A standard, galvanically isolated)

Other functions : Support time synchronization via communication message, SNTP (Simple Network Time Protocol) time synchronization, and IRIG-B time synchronization. Support the dot matrix printing function with serial port communication. Support the fault recording function

Product Introduction Technical Parameter Size

Product Introduction :
          The ​GWZC-9682 Generator Rotor Earth Fault Protection Relay​ is designed to detect and protect against ground faults in generator rotor windings, offering two-stage protection with alarm and trip functions for both low and high-resistance faults.

          GWZC-9682 Generator Rotor Earth Fault Protection Relay continuously monitors insulation resistance to detect early insulation degradation and includes self-testing for reliability.

          GWZC-9682 Generator Rotor Earth Fault Protection Relay​ Typically installed in generator protection panels, excitation control cabinets, or substation relay panels, this relay is essential for synchronous generators in power plants and industrial applications, ensuring safe operation and preventing rotor damage.

Product functionsANSI):

1.Single-Phase Ground Fault Protection (ANSI 50N/51N)
2.Double-Phase Ground Fault Protection (ANSI 50G/51G)

Electrical Specifications​

​Power Supply:​​

● AC: 85-264V, 47-63Hz (≤15% THD)
● DC: 100-370V (≤5% ripple)

​Rated AC Parameters:​​

● Voltage: 100V/√3 or 100V
● Current: 5A/1A
● Frequency: 50Hz

​Overload Capacity:​​

● Current Circuit: 2×In continuous | 10×In (10s) | 40×In (1s)
● Voltage Circuit: 1.5×Un continuous

​Power Consumption:​​

● Supply: <10W (static), ≤15W (trip)
● Current Circuit: ≤1VA/phase (5A) / ≤0.5VA/phase (1A)
● Voltage Circuit: ≤0.5VA/phase

​Digital Output:​​

● Dry contact (8A@250VAC / 30VDC)
● Dielectric: 4kVAC (coil-contact), 1kVAC (open contact)
● Operating Time: 5ms (typ) / 8ms (max)
● Mechanical Life: 100k operations

​Protection Performance

​Operating Range:​​

● Voltage: 0.5-120V (phase)
● Current: 0.02-20×In
● Zero-Seq Current: 0.05-20A
● Frequency: 35-65Hz | Delay: 0-100s

​Accuracy:​​

● Voltage/Current: ±2.5% or ±0.1V/±0.05A (whichever greater)
● Frequency: ±0.01Hz
● Settings: ±2.5%

​Trip Time:​​

● Instantaneous: ≤35ms (≥1.2× setting)
● Time-Delayed: ≤1% of setting or 35ms

Measurement & Monitoring​

​Range:​​

● Voltage: 0.5-120V | Current: 0.02-1.2×In

​Accuracy:​​

● V/I: ±0.2% | Frequency: ±0.01Hz | Other: 0.5%
● Time Sync: ≤2ms | SOE: ≤1ms

​Event Recording:​​

● 128 protection trips/operations
● 32 self-tests/fault waveforms (COMTRADE)

​Environmental & Mechanical​

​Operating Temp:​​

● Standard: -10°C to +55°C
● Extended: -40°C to +70°C*

​Storage Temp:​​ -40°C to +80°C
​Humidity:​​ 5-90% RH (non-condensing)
​Pressure:​​ 60-110 kPa
​Compliance:​​

● IEC 60255-21 (vibration/shock)
● IEC 61000-6 (EMC)

Related products More
GWZC-9000 Generator protection panel​
Generator Protection Panel
detail
GWZC-9581 Low-voltage generator protection relay
GWZC-9586 Low-voltage generator protection relay
detail
GWZC-9683 Generator Differential Protection Relay(87G)
GWZC-9683 Generator Differential Protection Relay
detail
GWZC-9681 Generator Backup Protection Relay
GWZC-9681 Generator Backup Protection Relay
detail
GWZC-9681C Generator Comprehensive Protection Relay
GWZW-9681C  Generator Comprehensive Protection Relay
detail
Technical Knowledge More
Ground Distance Protection (21G)
Differences Between Phase-to-Phase Distance Protection (21P) and Ground Distance Protection (21G)
The core difference between phase-to-phase distance protection and ground distance protection lies in the selection of measured quantities, fault response range, and connection methods. They complement each other to form a complete distance protection system for high-voltage transmission lines, both following the basic principle: operation if the measured impedance is less than the setting impedance.
2026/03/04
Generator Protection Panel
Generator Protection Relay Panel : Composition and Function
Integrating protection, measurement, and communication, the Generator Protection Relay Panel can realize the protection and control of various units, enabling unattended or minimally attended operation. It can achieve generator differential protection, rotor earth fault protection, stator earth fault protection, excitation protection, overcurrent protection, overvoltage protection, overload protection, backup protection, etc.
2025/11/25
Transformer Protection Relay Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.
2025/11/24
GWZC-9682 Generator Rotor Earth Fault Protection Relay
Generator Rotor Earth Fault Protection Relay Side View
Generator Rotor Earth Fault Protection Relay Rear View
Inquiry Consultation
产品表单
code img
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my