Back to smartelemfg Home
Contact us Merchants settle in
Back to smartelemfg Home
Home -Data downioad

Data name: GWZC-9811 Line Protection Relay Drawings and User Manual

File Format :msword - acad
File Size :4.37MB - 214.16KB
Data Introduction:
GWZC-9811 Line protection relay instructions
GWZC-9811 Line Protection Relay Diagrams:

1.Front Panel Diagram​
​2.Backplane Diagram​
3.​Wiring Diagram​
4.​Cutout Diagram​
5.​Dimensional Drawing

Note: For the latest version of documents, please contact the manufacturer.
GWZC-9811 Line protection relay engineering drawing
Related products More
GWZC-9586 Low-voltage generator protection relay
detail
GWZC-9605 Cable insulation monitoring device (IMD)​​(ANSI 64)
detail
GOWE-9000 Partial discharge online monitoring system
detail
GOWE-9000 Wireless Temperature Monitoring System for Substations
detail
GWZC-9604 Feeder Arc Flash Protection Relay
detail
News More
GWZC-9000 Drainage Pumping Station Automation System
Drainage Pumping Station Automation System—Forging a New Urban Flood Control Ecosystem
Drainage pump stations employ electromechanical systems for active water discharge, IoT and AI for precise regulation, and backup power for reliability. Digital twin platforms optimize decision-making with failure prediction and damage assessment. Each ¥100M investment reduces annual losses by ¥230M while saving 30% energy, as proven by Tokyo's flood defense system.
2025/07/23
Hydropower Station
Comprehensive Analysis of the Yarlung Zangbo River Hydropower Station
Massive hydropower potential, extreme seismic/geological challenges, unprecedented engineering (tunnels, dam, turbines), sensitive ecology, and critical transboundary impacts.​
2025/07/22
VT (Voltage Transformer ) Protection RelayRear View
Comprehensive Protection Relay: Full Analysis​
A comprehensive protection relay is an intelligent device that safeguards electrical systems by detecting faults (e.g., overcurrent, short circuits) and isolating affected equipment. It integrates multiple protection functions, ensures system reliability, and prevents damage. This guide covers its definition, working principle, protection targets, activation conditions, and outcomes.
2025/07/18
GWZC-9621 Distribution transformer protection relay
Three IEC International Standards for Electrical Relays Led by China Have Been Officially Released!
IEC 63522-6:2025 Electrical Relays – Tests and Measurements – Part 6: Contact Circuit Resistance (or Voltage Drop); IEC 63522-35:2025 Electrical Relays – Tests and Measurements – Part 35: Resistance to Cleaning Agents,IEC 63522-36:2025 Electrical Relays – Tests and Measurements – Part 36: Fire Hazard,Issuing Body: International Electrotechnical Commission (IEC)
2025/07/07
Technical More
Main Transformer-Protection Panel
Transformer Protection Relay Panel:Composition and Function
Transformer Protection Relay Panel is primarily used in automation systems for substations and distribution stations in power systems of 11kV, 33kV, 132kV and above. Its main function is to ensure that the transformer can promptly trip the faulty circuit in case of overload, short circuit, gas relay activation, and other abnormal operating conditions, thereby protecting the main transformer from damage and preventing the expansion of faults.
2025/11/24
Feeder Protection Relay
Common Protection Functions for Feeder Protection Relays?
Feeder protection relays are a type of line protection relay and serve as critical devices in distribution systems for protecting power cables (feeders). They integrate multiple protection functions to achieve comprehensive, reliable, and selective protection. Below are the commonly used protection functions of feeder protection relays, along with their corresponding ANSI codes.
2025/11/14
Transformer protection relay
Transformer Differential Protection(ANSI 87T): Working Principle, Function, and Setting Calculation
The working principle of the Transformer Differential Protection Relay is based on Kirchhoff's Current Law. This law states that the sum of currents entering a node is zero. Ideally, for a healthy (non-faulted) transformer, the current entering the primary winding should equal the current leaving the secondary winding (after accounting for the transformer's turns ratio and phase shift).
2025/11/12
Capacitor-protection-relay
Capacitor Unbalance Voltage Protection: Working Principle, Function, and Setting Calculation
Capacitor Unbalance Voltage Protection is used to monitor the voltage distribution among individual units within a capacitor bank, particularly in series-connected banks. Its operating principle is based on Kirchhoff's Voltage Law and capacitor voltage division. Under normal operating conditions, the voltage across each unit in the bank is relatively balanced, resulting in a minimal unbalance voltage. When a capacitor unit fails (e.g., internal short circuit, open circuit, or performance degradation), the voltage distribution becomes unequal, generating a significant unbalance voltage.
2025/11/12
Inquiry Consultation
+86-17621210051
+86-17621210051
+86-17621210051
+86-17621210051
home product email
live chat
my